Series N70 Model N76

3-Way Multi-Purpose Valve

The N70 line PeterPaul Hazardous location valves are UL listed and Certified for Non-Incendive Hazardous Locations — Class I, Div 2, Groups A,B,C and D - Class II, Div 2, Groups E,F and G - T3C Temperature rating

• Largest direct acting (non-piloted) valve we manufacture.

• Large orifice.

• High flow.

• Will operate effectively at very low pressures or vacuum.


  • SPECIFICATIONS
  • 2-D & 3-D CAD DRAWING
  • FLOW CHART
  • NOMENCLATURE

VALVE SPECIFICATIONS

MAX. OPER.
PRESS. DIFF.
ORIFICE SIZE CV FACTOR CONDUIT HOUSING
AC DC N.C. N.O. N.C. N.O. 1/4 NPT PORTS
225 225 1/16 1/16 .09 .09 N76JJ9ZCP
150 150 3/32 3/32 .22 .22 N76KK9ZCP
100 100 1/8 1/8 .35 .35 N76NN9ZCP
75 75 5/32 5/32 .45 .45 N76OO9ZCP
60 60 3/16 3/16 .50 .50 N76PP9ZCP

WHEN ORDERING VALVES OR REPAIR PACKS ADD VOLTAGE AND FREQUENCY TO COMPLETE
VALVE NUMBER. EXAMPLES: VALVE (N76KK9ZGP-120/60) REPAIR PACK (KN76KKX-AC)

OPERATING CONDITIONS

Media: Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range: Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials: See table above.
Burst Pressure: 4000 PSI
Leakage: Bubble tight for standard valves.
Vacuum: To 5 Microns*

ELECTRICAL CHARACTERISTICS

Coil Voltage: 12 to 1150V AC 60 HZ. and 11 to 1035V AC 50 HZ. — 2.5 to 220V DC
Nominal Power: AC — 18.0 Watts DC — 16.0 Watts
Coil Construction: Potted Class F. (Class H optional)
Typical Response Time on Air: 4 - 16 Milliseconds
Operating Speed: Up to 600 CPM
Duty Cycle: Continuous

MECHANICAL CHARACTERISTICS

Body: Stainless Steel (Std.) or Brass (Opt.)
Internal Components: Stainless Steel
Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter: See table above.
Porting: Standard 1/4" NPT (other ports available).*
Housing: 1/2" NPT conduit *
Listings:UL listed and Certified for Non-Incendive Hazardous Locations — Class I, Div 2, Groups A,B,C and D - Class II, Div 2, Groups E,F and G - T3C Temperature rating.

Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
Valve Weight: Conduit Valve: 2.06 lb
Repair Packs: See table below.
Options: Alternate Port Locations, Metering and Alternate Elastomers * Consult representative or factory for options and specifications.

Series N70 General Purpose Valves Conduit


MODEL N72 1/4-18 NPT 2WNC CONDUIT CONNECTION

MODEL N72 BODY OPTION "E" 2WNC CONDUIT CONNECTION

MODEL N72 BODY OPTION "O" 2WNC CONDUIT CONNECTION

MODEL N72 BODY OPTION "R" 2WNC CONDUIT CONNECTION

MODEL N72 1/4-18 NPT 2WNC CONDUIT CONNECTION

MODEL N72 METERED BODY 2WNC CONDUIT CONNECTION

Series N70 General Purpose Valves Conduit/Bracket Connection


MODEL N72 1/4-18 NPT 2WNC CONDUIT/BRACKET CONNECTION

MODEL N72 BODY OPTION "E" 2WNC CONDUIT/BRACKET CONNECTION

MODEL N72 BODY OPTION "O" 2WNC CONDUIT/BRACKET CONNECTION

MODEL N72 BODY OPTION "R" 2WNC CONDUIT/BRACKET CONNECTION

MODEL N72 MANUAL OVERRIDE 2WNC CONDUIT/BRACKET CONNECTION

MODEL N72 MANUAL OVERRIDE 2WNC CONDUIT/BRACKET CONNECTION
Series 70 Flow Charts