Series EL 50 Model EL52

Low Wattage Hazardous Location
2-Way Normally Closed Valve

Peter Paul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.

• Miniature Hazardous Location valves using even less power than an E52.
• Flame-Proof construction.
• High quality engineering.

52flow

  • SPECIFICATIONS
  • 2-D & 3-D CAD DRAWING
  • FLOW CHART
  • NOMENCLATURE

VALVE SPECIFICATIONS

MAX. OPER.
PRESS. DIFF.
ORIFICE SIZE CV FACTOR
AC DC N.C. N.C. VALVE NUMBER
120 120 1/32 .022 EL52G8DCCM
80 80 3/64 .055 EL52H8DCCM
50 50 1/16 .075 EL52J8DCCM

WHEN ORDERING VALVES OR REPAIR KITS ADD VOLTAGE AND FREQUENCY TO COMPLETE
VALVE NUMBER. EXAMPLES: VALVE (EL52H8DCCM-120/60) REPAIR KIT (5KEL52H-AC)

OPERATING CONDITIONS

Media: Air and other common gases and common refrigerants except ammonia, city gas supplies by public utilities, Nos. 1 and 2 fuel oils, oils having viscosities not more than 40, SU at 100° F, steam, some hydraulic and water or other aqueous non-flammable liquids. Some media require special seal material. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range: Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials: See table above.
Burst Pressure: 4000 PSI
Leakage: Bubble tight for standard valves.
Vacuum: To 5 Microns*

ELECTRICAL CHARACTERISTICS

Coil Voltage: 12 to 240V AC 60 HZ. — 5 to 120V DC
Nominal Power: AC — 1.8 Watts DC — 1.8 Watts
Coil Construction: Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air: 4 - 16 Milliseconds
Operating Speed: Up to 600 CPM
Duty Cycle: Continuous

MECHANICAL CHARACTERISTICS

Body: Stainless Steel (Std.)
Internal Components: Stainless Steel
Elastomers: Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter: See table above.
Porting: 1/8" NPT (Std.)
Housing: Flame-Proof construction with 1/2" NPT conduit
Listings: Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D - Class II, Div 1, Groups E, F, and G: Div 2, Groups A, B, C, D, E, F, and G.
Life Expectancy: Millions of cycles, depending on application, lubrication, etc.
Valve Weight: 0.65 lbs
Repair Kits: See table above.
Options: Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*

* Consult representative or factory for options and specifications.

Series EL 50 Hazardous Location Valves


MODEL EL52
2WNC
EXPLOSION PROOF

MODEL EL52 10-32 PORTS
2WNC
EXPLOSION PROOF

MODEL EL52 BODY OPTION "E"
2WNC
EXPLOSION PROOF

MODEL EL52 BODY OPTION "O"
2WNC
EXPLOSION PROOF

MODEL EL52 BODY OPTION "R"
2WNC
EXPLOSION PROOF

MODEL EL52 METERED BODY
2WNC