Series 20 Model MLVN26 (FIXED POLARITY) CLASS I DIV II

Series 20 Model MLVN26 (FIXED POLARITY) Class I DIV II
Series 20 Model MLVN26 (FIXED POLARITY) CLASS I DIV II solenoid operator
DIN coil (3 terminals with ground) wiring diagram
Series 20 Model MLVN26 (FIXED POLARITY) CLASS I DIV II flow diagram

3-Way Multipurpose Fixed Polarity Class I Div II Magnet Latching Valve - The N20 Latching Valves are CSA listed and certified for non-incendive Hazardous Location Class 1, Div 2, Groups A, B, C and D; T6 temperature rating. This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

Valve specifications — Series 20 Model MLVN26 (FIXED POLARITY) CLASS I DIV II
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
DCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS
1751/321/32.024.024N26GG7X4LM-∆N26GG9Z4LM-∆
1103/643/64.052.052N26HH7X4LM-∆N26HH9Z4LM-∆
501/161/16.095.052N26JJ7X4LM-∆N26JJ9Z4LM-∆
153/323/32.156.156N26KK7X4LM-∆N26KK9Z4LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code -Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N26JJ7X4LM 12/DC) repair pack (KN26JJ4L DC)


Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” OR 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*
Stainless Steel
Certification
North American

Series 20 Model MLVN25 (FIXED POLARITY) CLASS I DIV II

Series 20 Model MLVN25 (FIXED POLARITY) CLASS I DIV II
Series 20 Model MLVN25 (FIXED POLARITY) CLASS I DIV II solenoid operator
DIN coil (3 terminals with ground) wiring diagram
Series 20 Model MLVN25 (FIXED POLARITY) CLASS I DIV II flow diagram

3-Way Directional Control Fixed Polarity Class I Div II Magnet Latching Valve - The N20 Latching Valves are CSA listed and certified for non-incendive Hazardous Location Class 1, Div 2, Groups A, B, C and D; T6 temperature rating. This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

Valve specifications — Series 20 Model MLVN25 (FIXED POLARITY) CLASS I DIV II
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
DCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS
500*1/321/32.024.024N25GG7X4LM-∆N25GG9Z4LM-∆
2503/643/64.052.052N25HH7X4LM-∆N25HH9Z4LM-∆
1801/163/64.095.052N25JH7X4LM-∆N25JH9Z4LM-∆
1551/161/16.095.095N25JJ7X4LM-∆N25JJ9Z4LM-∆
1003/323/32.156.156N25KK7X4LM-∆N25KK9Z4LM-∆
801/83/32.214.156N25NK7X4LM-∆N25NK9Z4LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N25JJ7X4LM 12/DC) repair pack (KN25JJ4L DC)


Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” OR 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*
Stainless Steel
Certification
North American

Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Piped Exhaust

SERIES 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - PIPED EXHAUST
Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Piped Exhaust solenoid operator
DIN coil (3 terminals with ground) wiring diagram
Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Piped Exhaust flow diagram

3-Way Fixed Polarity Class I Div II Magnet Latching Valve — Piped Exhaust - The N20 Latching Valves are CSA listed and certified for non-incendive Hazardous Location Class 1, Div 2, Groups A, B, C and D; T6 temperature rating. This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

Valve specifications — Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Piped Exhaust
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZEORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
DCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS
3851/321/32.024.024N23GG7X4LM-∆N23GG9Z4LM-∆
3651/323/64.024.052N23GH7X4LM-∆N23GH9Z4LM-∆
1503/641/16.052.095N23HJ7X4LM-∆N23HJ9Z4LM-∆
1001/161/16.095.095N23JJ7X4LM-∆N23JJ9Z4LM-∆
1001/163/32.095.156N23JK7X4LM-∆N23JK9Z4LM-∆
653/323/32.214.156N23KK7X4LM-∆N23KK9Z4LM-∆
401/83/32.404.156N23NK7X4LM-∆N23NK9Z4LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N23JJ7X4LM 12/DC) repair pack (KN23JJ4L DC)

Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” or 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*
Stainless Steel
Certification
North American

Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Exhaust to Atmosphere

Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Exhaust to Atmosphere
DIN coil (3 terminals with ground) wiring diagram
Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Exhaust to Atmosphere flow diagram

3-Way Fixed Polarity Class I Div II Magnet Latching Valve — Exhaust to Atmosphere - The N20 Latching Valves are CSA listed and certified for non-incendive Hazardous Location Class 1, Div 2, Groups A, B, C and D; T6 temperature rating. This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

Valve specifications — Series 20 Model MLVN23 (FIXED POLARITY) CLASS I DIV II - Exhaust to Atmosphere
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZEORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
DCINLETEXHINLETEXH1/8 NPT PORTS1/4 NPT PORTS
3851/321/32.024.024N23GG7D4LM-∆N23GG9D4LM-∆
3651/323/64.024.052N23GH7D4LM-∆N23GH9D4LM-∆
1503/641/16.052.095N23HJ7D4LM-∆N23HJ9D4LM-∆
1001/161/16.095.095N23JJ7D4LM-∆N23JJ9D4LM-∆
1001/163/32.095.156N23JK7D4LM-∆N23JK9D4LM-∆
653/323/32.214.156N23KK7D4LM-∆N23KK9D4LM-∆
401/83/32.404.156N23NK7D4LM-∆N23NK9D4LM-∆
203/163/32.500.156N23PK7D4LM-∆N23PK9D4LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N23JJ7D4LM 12/DC) repair pack (KN23JJ4L DC)


Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” or 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*
Stainless Steel
Certification
North American

Series 20 Model MLVNH22 (FIXED POLARITY) CLASS I DIV II

Series 20 Model MLVNH22 (FIXED POLARITY) CLASS I DIV II
Series 20 Model MLVNH22 (FIXED POLARITY) CLASS I DIV II solenoid operator
DIN coil (3 terminals with ground) wiring diagram
Series 20 Model MLVNH22 (FIXED POLARITY) CLASS I DIV II flow diagram

2-Way High Pressure Fixed Polarity Class I Div II Magnet Latching Valve - The N20 Latching Valves are CSA listed and certified for non-incendive Hazardous Location Class 1, Div 2, Groups A, B, C and D; T6 temperature rating. This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited, as it only uses power during latching and un-latching. It is also valuable in equipment where coil heating, due to the continuous application of power, is undesirable. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.

Valve specifications — Series 20 Model MLVNH22 (FIXED POLARITY) CLASS I DIV II
Gas Pressure RatingsORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
1/8 NPT PORTS1/4 NPT PORTS
2500 PSI*0.0250.010NH22M7D4LM-∆NH22M9D4LM-∆
1000 PSI*1/320.022NH22G7D4LM-∆NH22G9D4LM-∆
750 PSI*3/640.041NH22H7D4LM-∆NH22H9D4LM-∆
300 PSI1/160.065NH22J7D4LM-∆NH22J9D4LM-∆
125 PSI3/320.100NH22K7D4LM-∆NH22K9D4LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code -Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (NH22J7D4LM 12/DC) repair pack (KNH22J4L DC)

Coil Voltage
6, 9, 12, 24/DC
Nominal Power
15 Watts
Coil Construction
Molded (Std.), Non-molded Class A and Potted Class F or Class H (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM with gas media
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Sealing Pin
Kel-F (Std.)
Orifice Diameter
See table above.
Porting
1/8" and 1/4" NPT (other ports available).
Housing
Grommet and 1/2" NPT conduit – many options available.*
Mounting
Any orientation
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.13 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air and other non-corrosive gasses, water and oil.
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
10,000 PSI
Leakage
Bubbletight (with polymer sealing pins)
Stainless Steel (Std.)
Certification
North American

Series 20 Model MLVN22 (FIXED POLARITY) CLASS I DIV II

Series 20 Model MLVN22 (FIXED POLARITY) CLASS I DIV II
Series 20 Model MLVN22 (FIXED POLARITY) CLASS I DIV II solenoid operator
DIN coil (3 terminals with ground) wiring diagram
Series 20 Model MLVN22 (FIXED POLARITY) CLASS I DIV II flow diagram

2-Way Fixed Polarity Class I DIV II Magnet Latching Valve - The N20 Latching Valves are CSA listed and certified for non-incendive Hazardous Location Class 1, Div 2, Groups A, B, C and D; T6 temperature rating. This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to the continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

Valve specifications — Series 20 Model MLVN22 (FIXED POLARITY) CLASS I DIV II
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
DC1/8 NPT PORT1/4 NPT Port
500*1/32.024N22G7D4LM-∆N22G9D4LM-∆
500*3/64.052N22H7D4LM-∆N22H9D4LM-∆
2151/16.095N22J7D4LM-∆N22J9D4LM-∆
1503/32.156N22K7D4LM-∆N22K9D4LM-∆
1201/8.214N22N7D4LM-∆N22N9D4LM-∆
805/32.404N22O7D4LM-∆N22O9D4LM-∆
353/16.500N22P7D4LM-∆N22P9D4LM-∆
251/4.700N22R7D4LM-∆N22R9D4LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code -Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N22J7D4LM 12/DC) repair pack (KN22J4L DC)


Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” OR 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*
Stainless Steel
Certification
North American
We will be closed