PFAS Declaration
PeterPaul’s model H23 has a dual operator valve that allows the same media control as a three-way normally closed valve but at much higher pressure ratings than previously available. To function as a 3-way normally closed valve, operators must be alternately energized and de-energized. Pressure applied to the “IN” port must always be equal to or greater than the pressure in the “CYL” port. Air and other non-corrosive gases, water, and oil.
| GAS PRESSURE RATINGS | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | ||||
|---|---|---|---|---|---|---|---|
| AC | DC | 1/4 NPT PORTS | |||||
| 3000* | 3000* | 1/32 | .022 | H23GG19DCMG | |||
| 2500* | 1500* | 3/64 | .041 | H23HH19DCMG | |||
| 1750* | 500 | 1/16 | .065 | H23JJ19DCMG | |||
| 650* | 100 | 3/32 | .100 | H23KK19DCMG | |||
| LIQUID PRESSURE RATINGS | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | ||||
| AC | DC | 1/4 NPT PORTS | |||||
| 3000* | 3000* | 1/32 | .022 | H23GG19DCML | |||
| 1500* | 1500* | 3/64 | .041 | H23HH19DCML | |||
| 1000* | 500 | 1/16 | .065 | H23JJ19DCML | |||
| 300 | 100 | 3/32 | .100 | H23KK19DCML | |||
* FKM seals not recommended for pressure above 500 psi.
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (H23JJ19DCMG 120/60) repair pack (KH23JJ AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OH23JJDDCMG 120/60)

3-Way Fixed Polarity Magnet Latching Valve — Exhaust to Atmosphere - This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.
Common Black wire set to Neutral (-) a. Pulse Yellow lead to Positive (+) to latch b. Pulse Blue lead to Positive (+) to un-latch
Common Black wire set to Positive (+) a. Pulse Yellow lead to Neutral (-) to un-latch b. Pulse Blue lead to Neutral (-) to latch
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | ORIFICE SIZE | CV FACTOR | VALVE NUMBER DIN COIL (3 TERMINALS WITH GROUND) | VALVE NUMBER 3 WIRE COIL | |||
|---|---|---|---|---|---|---|---|---|
| DC | INLET | EXH | INLET | EXH | 1/8 NPT PORTS | 1/4 NPT PORTS | 1/8 NPT PORTS | 1/4 NPT PORTS |
| 365 | 1/32 | 3/64 | .024 | .052 | 23GH7D4LM-∆ | 23GH9D4LM-∆ | 23GH7D3LM-∆ | 23GH9D3LM-∆ |
| 385 | 1/32 | 1/32 | .024 | .024 | 23GG7D4LM-∆ | 23GG9D4LM-∆ | 23GG7D3LM-∆ | 23GG9D3LM-∆ |
| 150 | 3/64 | 1/16 | .052 | .095 | 23HJ7D4LM-∆ | 23HJ9D4LM-∆ | 23HJ7D3LM-∆ | 23HJ9D3LM-∆ |
| 100 | 1/16 | 1/16 | .095 | .095 | 23JJ7D4LM-∆ | 23JJ9D4LM-∆ | 23JJ7D3LM-∆ | 23JJ9D3LM-∆ |
| 100 | 1/16 | 3/32 | .095 | .156 | 23JK7D4LM-∆ | 23JK9D4LM-∆ | 23JK7D3LM-∆ | 23JK9D3LM-∆ |
| 65 | 3/32 | 3/32 | .214 | .156 | 23KK7D4LM-∆ | 23KK9D4LM-∆ | 23KK7D3LM-∆ | 23KK9D3LM-∆ |
| 40 | 1/8 | 3/32 | .404 | .156 | 23NK7D4LM-∆ | 23NK9D4LM-∆ | 23NK7D3LM-∆ | 23NK9D3LM-∆ |
| 20 | 3/16 | 3/32 | .500 | .156 | 23PK7D4LM-∆ | 23PK9D4LM-∆ | 23PK7D3LM-∆ | 23PK9D3LM-∆ |
* FKM seals not recommended for pressures of 500 psi and above.
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (23JJ7D3LM 12/DC) repair pack (K23JJ3L DC)





A UL and CSA listed, low watt, miniature hazardous location valve with minimal space and energy requirements in volatile environments. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | NORTH AMERICAN VALVE NUMBER | |||||
|---|---|---|---|---|---|---|---|---|
| GAS | LIQUID | |||||||
| AC | DC | AC | DC | N.C. | N.O. | N.C. | N.O. | |
| 215 | 135 | 215 | 135 | 1/32 | 1/32 | .022 | .020 | ELW53GG8XCCP |
| 215 | 120 | 120 | 65 | 1/32 | 3/64 | .022 | .048 | ELW53GH8XCCP |
| 135 | 50 | 40 | 30 | 1/32 | 1/16 | .022 | .075 | ELW53GJ8XCCP |
| 70 | 35 | 30 | 20 | 1/32 | 1/16 | .022 | .134 | ELW53GV8XCCP |
| 55 | 30 | 25 | 15 | 1/32 | 3/32 | .022 | .150 | ELW53GK8XCCP |
| 120 | 70 | 120 | 65 | 3/64 | 3/64 | .055 | .048 | ELW53HH8XCCP |
| 120 | 50 | 40 | 30 | 3/64 | 1/16 | .055 | .075 | ELW53HJ8XCCP |
| 70 | 35 | 30 | 20 | 3/64 | 1/16 | .055 | .134 | ELW53HV8XCCP |
| 55 | 30 | 25 | 15 | 3/64 | 3/32 | .055 | .150 | ELW53HK8XCCP |
| 85 | 40 | 40 | 30 | 1/16 | 1/16 | .075 | .075 | ELW53JJ8XCCP |
| 70 | 35 | 30 | 20 | 1/16 | 1/16 | .075 | .134 | ELW53JV8XCCP |
| 55 | 30 | 25 | 15 | 1/16 | 3/32 | .075 | .150 | ELW53JK8XCCP |
| 50 | 30 | 30 | 20 | 5/64 | 1/16 | .134 | .134 | ELW53VV8XCCP |
| 50 | 30 | 25 | 15 | 5/64 | 3/32 | .134 | .150 | ELW53VK8XCCP |
| 35 | 20 | 25 | 15 | 5/64 | 3/32 | .156 | .150 | ELW53KK8XCCP |







General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants, and many other media by the use of different seals. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | |||||
|---|---|---|---|---|---|---|---|---|
| GAS | LIQUID | |||||||
| AC | DC | AC | DC | N.C. | N.O. | N.C. | N.O. | |
| 215 | 135 | 215 | 135 | 1/32 | 1/32 | .022 | .020 | SLW53GG8XCCP |
| 215 | 120 | 120 | 65 | 1/32 | 3/64 | .022 | .048 | SLW53GH8XCCP |
| 135 | 50 | 40 | 30 | 1/32 | 1/16 | .022 | .075 | SLW53GJ8XCCP |
| 70 | 35 | 30 | 20 | 1/32 | 1/16 | .022 | .134 | SLW53GV8XCCP |
| 55 | 30 | 25 | 15 | 1/32 | 3/32 | .022 | .150 | SLW53GK8XCCP |
| 120 | 70 | 120 | 65 | 3/64 | 3/64 | .055 | .048 | SLW53HH8XCCP |
| 120 | 50 | 40 | 30 | 3/64 | 1/16 | .055 | .075 | SLW53HJ8XCCP |
| 70 | 35 | 30 | 20 | 3/64 | 1/16 | .055 | .134 | SLW53HV8XCCP |
| 55 | 30 | 25 | 15 | 3/64 | 3/32 | .055 | .150 | SLW53HK8XCCP |
| 85 | 40 | 40 | 30 | 1/16 | 1/16 | .075 | .075 | SLW53JJ8XCCP |
| 70 | 35 | 30 | 20 | 1/16 | 1/16 | .075 | .134 | SLW53JV8XCCP |
| 55 | 30 | 25 | 15 | 1/16 | 3/32 | .075 | .150 | SLW53JK8XCCP |
| 50 | 30 | 30 | 20 | 5/64 | 1/16 | .134 | .134 | SLW53VV8XCCP |
| 50 | 30 | 25 | 15 | 5/64 | 3/32 | .134 | .150 | SLW53VK8XCCP |
| 35 | 20 | 25 | 15 | 5/64 | 3/32 | .156 | .150 | SLW53KK8XCCP |






General purpose valve for pneumatic applications. The versatility of these valves is increased to include the handling of hot air, refrigerants, and many other media by the use of different seals. Air and other gases are compatible with standard Buna seals.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET 1/8" NPT | VALVE NUMBER CONDUIT 1/8" NPT | ||
|---|---|---|---|---|---|---|
| GAS | ||||||
| DC | N.C. | N.O. | N.C. | N.O. | ||
| 120 | 1/32 | 1/32 | .022 | .022 | LLW53G8XGM | LLW53G8XCM |










































General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants, and many other media by the use of different seals. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET 1/8" NPT | VALVE NUMBER CONDUIT 1/8" NPT | |||||
|---|---|---|---|---|---|---|---|---|---|
| GAS | LIQUID | ||||||||
| AC | DC | AC | DC | N.C. | N.O. | N.C. | N.O. | ||
| 215 | 135 | 215 | 135 | 1/32 | 1/32 | .022 | .022 | LW53GG8XGM | LW53GG8XCM |
| 215 | 120 | 120 | 65 | 1/32 | 3/64 | .022 | .048 | LW53GH8XGM | LW53GH8XCM |
| 135 | 50 | 40 | 30 | 1/32 | 1/16 | .022 | .075 | LW53GJ8XGM | LW53GJ8XCM |
| 70 | 35 | 30 | 20 | 1/32 | 5/64 | .022 | .134 | LW53GV8XGM | LW53GV8XCM |
| 55 | 30 | 25 | 15 | 1/32 | 3/32 | .022 | .156 | LW53GK8XGM | LW53GK8XCM |
| 120 | 70 | 120 | 65 | 3/64 | 3/64 | .055 | .048 | LW53HH8XGM | LW53HH8XCM |
| 120 | 50 | 40 | 30 | 3/64 | 1/16 | .055 | .075 | LW53HJ8XGM | LW53HJ8XCM |
| 70 | 35 | 30 | 20 | 3/64 | 5/64 | .055 | .134 | LW53HV8XGM | LW53HV8XCM |
| 55 | 30 | 25 | 15 | 3/64 | 3/32 | .055 | .156 | LW53HK8XGM | LW53HK8XCM |
| 85 | 40 | 40 | 30 | 1/16 | 1/16 | .075 | .075 | LW53JJ8XGM | LW53JJ8XCM |
| 70 | 35 | 30 | 20 | 1/16 | 5/64 | .075 | .134 | LW53JV8XGM | LW53JV8XCM |
| 55 | 30 | 25 | 15 | 1/16 | 3/32 | .075 | .156 | LW53JK8XGM | LW53JK8XCM |
| 50 | 30 | 30 | 20 | 5/64 | 5/64 | .134 | .134 | LW53VV8XGM | LW53VV8XCM |
| 50 | 30 | 25 | 15 | 5/64 | 3/32 | .134 | .156 | LW53VK8XGM | LW53VK8XCM |
| 35 | 20 | 25 | 15 | 3/32 | 3/32 | .150 | .156 | LW53KK8XGM | LW53KK8XCM |










































General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants, and many other media by the use of different seals. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET 1/8" NPT | VALVE NUMBER CONDUIT 1/8" NPT | |||||
|---|---|---|---|---|---|---|---|---|---|
| GAS | LIQUID | ||||||||
| AC | DC | AC | DC | N.C. | N.O. | N.C. | N.O. | ||
| 215 | 135 | 215 | 135 | 1/32 | 1/32 | .022 | .022 | LW53GG8DGM | LW53GG8DCM |
| 215 | 120 | 120 | 65 | 1/32 | 3/64 | .022 | .048 | LW53GH8DGM | LW53GH8DCM |
| 135 | 50 | 40 | 30 | 1/32 | 1/16 | .022 | .075 | LW53GJ8DGM | LW53GJ8DCM |
| 70 | 35 | 30 | 20 | 1/32 | 5/64 | .022 | .134 | LW53GV8DGM | LW53GV8DCM |
| 55 | 30 | 25 | 15 | 1/32 | 3/32 | .022 | .156 | LW53GK8DGM | LW53GK8DCM |
| 120 | 70 | 120 | 65 | 3/64 | 3/64 | .055 | .048 | LW53HH8DGM | LW53HH8DCM |
| 120 | 50 | 40 | 30 | 3/64 | 1/16 | .055 | .075 | LW53HJ8DGM | LW53HJ8DCM |
| 70 | 35 | 30 | 20 | 3/64 | 5/64 | .055 | .134 | LW53HV8DGM | LW53HV8DCM |
| 55 | 30 | 25 | 15 | 3/64 | 3/32 | .055 | .156 | LW53HK8DGM | LW53HK8DCM |
| 85 | 40 | 40 | 30 | 1/16 | 1/16 | .075 | .075 | LW53JJ8DGM | LW53JJ8DCM |
| 70 | 35 | 30 | 20 | 1/16 | 5/64 | .075 | .134 | LW53JV8DGM | LW53JV8DCM |
| 55 | 30 | 25 | 15 | 1/16 | 3/32 | .075 | .156 | LW53JK8DGM | LW53JK8DCM |
| 50 | 30 | 30 | 20 | 5/64 | 5/64 | .134 | .134 | LW53VV8DGM | LW53VV8DCM |
| 50 | 30 | 25 | 15 | 5/64 | 3/32 | .134 | .156 | LW53VK8DGM | LW53VK8DCM |
| 35 | 20 | 25 | 15 | 3/32 | 3/32 | .150 | .156 | LW53KK8DGM | LW53KK8DCM |
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (LW53JJ8DGM 120/60) repair pack (KLW53JJD AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OLW53JJDDGM 120/60)








Easily interfaced with circuit boards and miniaturized components. The versatility is for connecting electronic signals to pneumatic outputs. The small size is ideal for stand alone (with #10-32 UNF-2B ports) or multiple valves mounted on one manifold. Air and other common gases — filtration recommended — 30 microns or less.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | ||
|---|---|---|---|---|---|
| DC | N.C. | N.O. | N.C. | N.O. | LEADWIRE |
| 145 | 0.6 mm | 0.6 mm | .010 | .010 | 586AA19PGM |
| 100 | 0.8 mm | 0.8 mm | .020 | .020 | 586FF19PGM |
| 50 | 1.0 mm | 1.0 mm | .030 | .030 | 586MM19PGM |
| 20 | 1.2 mm | 1.2 mm | .034 | .034 | 586WW19PGM |
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (586MM19PGM 12/DC) repair pack (K586MM19 DC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O586MMDPGM 12/DC)





PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.
| + MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | NORTH AMERICAN VALVE NUMBER | IECEx/ATEX VALVE NUMBER | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| AC | DC | INLET | EXH | INLET | EXH | 1/8 NPT PORTS | 1/4 NPT PORTS | 1/8 NPT PORTS | 1/4 NPT PORTS | ||
| 400 | 400 | 1/32 | 1/32 | .024 | .024 | E23GG7XCCM-∆ | E23GG9ZCCM-∆ | EA23GG7XCCM-∆ | EA23GG9ZCCM-∆ | ||
| 150 | (200) | 150 | (200) | 3/64 | 1/16 | .052 | .095 | E23HJ7XCCM-∆ | E23HJ9ZCCM-∆ | EA23HJ7XCCM-∆ | EA23HJ9ZCCM-∆ |
| 100 | (135) | 100 | (135) | 1/16 | 1/16 | .095 | .095 | E23JJ7XCCM-∆ | E23JJ9ZCCM-∆ | EA23JJ7XCCM-∆ | EA23JJ9ZCCM-∆ |
| 100 | (135) | 100 | (135) | 1/16 | 3/32 | .095 | .156 | E23JK7XCCM-∆ | E23JK9ZCCM-∆ | EA23JK7XCCM-∆ | EA23JK9ZCCM-∆ |
| 75 | (100) | 75 | (100) | 3/32 | 3/32 | .156 | .156 | E23KK7XCCM-∆ | E23KK9ZCCM-∆ | EA23KK7XCCM-∆ | EA23KK9ZCCM-∆ |
| 50 | (70) | 50 | (70) | 1/8 | 3/32 | .284 | .156 | E23NK7XCCM-∆ | E23NK9ZCCM-∆ | EA23NK7XCCM-∆ | EA23NK9ZCCM-∆ |
| 35 | (40) | 35 | (40) | 1/8 | 1/8 | .284 | .227 | E23NN7XCCM-∆^ | E23NN9ZCCM-∆ | EA23NN7XCCM-∆^ | EA23NN9ZCCM-∆ |
| 20 | 20 | 3/16 | 3/32 | .500 | .156 | E23PK7XCCM-∆ | E23PK9ZCCM-∆ | EA23PK7XCCM-∆ | EA23PK9ZCCM-∆ | ||
| 20 | 20 | 3/16 | 1/8 | .500 | .227 | E23PN7XCCM-∆^ | E23PN9ZCCM-∆ ^ | EA23PN7XCCM-∆^ | EA23PN9ZCCM-∆ ^ | ||
| 15 | — | 1/4 | 3/32 | .700 | .156 | E23RK7XCCM-∆ | E23RK9ZCCM-∆ ^ | EA23RK7XCCM-∆ | EA23RK9ZCCM-∆ ^ | ||
| 15 | — | 1/4 | 1/8 | .700 | .227 | E23RN7XCCM-∆ ^ | E23RN9ZCCM-∆^ | EA23RN7XCCM-∆ ^ | EA23RN9ZCCM-∆^ | ||
^ VALVES WITH 1/8 ORIFICE ARE NOT UL OR CSA LISTED
+ Ratings in brackets are optional extended ratings; consult factory.
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (E23KK9ZCCM-∆ 120/60) repair pack (2KE23KKZ AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE23KKDZCCM-∆ 120/60)




Coming soon.