Series 20 Model MLV26 (FIXED POLARITY)

Series 20 Model MLV26 (FIXED POLARITY)
Series 20 Model MLV26 (FIXED POLARITY) solenoid operator
DIN coil (3 terminals with ground) wiring diagram
3 wire coil wiring diagram
Series 20 Model MLV26 (FIXED POLARITY) flow diagram

3-Way Multi-Purpose Fixed Polarity Magnet Latching Valve - This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

Neutral (−) a. Pulse Yellow lead to Positive (+) to latch   b. Pulse Blue lead to Positive (+) to un-latch  

Positive (+) a. Pulse Yellow lead to Neutral (−) to un-latch   b. Pulse Blue lead to Neutral (−) to latch  

Valve specifications — Series 20 Model MLV26 (FIXED POLARITY)
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
VALVE NUMBER
3 WIRE COIL
DCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS1/8 NPT PORTS1/4 NPT PORTS
1751/321/32.024.02426GG7X4LM-∆26GG9Z4LM-∆26GG7X3LM-∆26GG9Z3LM-∆
1103/643/64.052.05226HH7X4LM-∆26HH9Z4LM-∆26HH7X3LM-∆26HH9Z3LM-∆
501/161/16.095.05226JJ7X4LM-∆26JJ9Z4LM-∆26JJ7X3LM-∆26JJ9Z3LM-∆
153/323/32.156.15626KK7X4LM-∆26KK9Z4LM-∆26KK7X3LM-∆26KK9Z3LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (26JJ7X3LM 12/DC) repair pack (K26JJ3L DC)


Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” OR 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lbs average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*
Stainless Steel

Series 20 Model MLV25 (FIXED POLARITY)

Series 20 Model MLV25 (FIXED POLARITY)
Series 20 Model MLV25 (FIXED POLARITY) solenoid operator
DIN coil (3 terminals with ground) wiring diagram
3 wire coil wiring diagram
Series 20 Model MLV25 (FIXED POLARITY) flow diagram

3-Way Directional Control Fixed Polarity Magnet Latching Valve - This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

Common Black wire set to Neutral (-) a. Pulse Yellow lead to Positive (+) to latch   b. Pulse Blue lead to Positive (+) to un-latch  

Common Black wire set to Positive (+) a. Pulse Yellow lead to Neutral (-) to un-latch   b. Pulse Blue lead to Neutral (-) to latch  

Valve specifications — Series 20 Model MLV25 (FIXED POLARITY)
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER DIN COIL
(3 TERMINALS WITH GROUND)
VALVE NUMBER
3 WIRE COIL
DCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS1/8 NPT PORTS1/4 NPT PORTS
500*1/321/32.024.02425GG7X4LM-∆25GG9Z4LM-∆25GG7X3LM-∆25GG9Z3LM-∆
2503/643/64.052.05225HH7X4LM-∆25HH9Z4LM-∆25HH7X3LM-∆25HH9Z3LM-∆
1801/163/64.095.05225JH7X4LM-∆25JH9Z4LM-∆25JH7X3LM-∆25JH9Z3LM-∆
1551/161/16.095.09525JJ7X4LM-∆25JJ9Z4LM-∆25JJ7X3LM-∆25JJ9Z3LM-∆
1003/323/32.156.15625KK7X4LM-∆25KK9Z4LM-∆25KK7X3LM-∆25KK9Z3LM-∆
801/83/32.214.15625NK7X4LM-∆25NK9Z4LM-∆25NK7X3LM-∆25NK9Z3LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (25JJ7X3LM 12/DC) repair pack (K25JJ3L DC)


Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” OR 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lbs average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*