Puerto Rico ISO 9001 – Peter Paul Electric Inc.
Peter Paul Electronics Co., Inc. is proud to announce ISO 9001 certification. PeterPaul started formally implementing ISO 9001 Certification in 2005. Over a 5-1/2 year span, the company’s operating processes were documented and modified where necessary, to not only comply with ISO 9001 certification requirements, but to establish a robust Quality Management System (QMS).
Super valves that have ratings that formerly required valves of much greater size. They are higher flow at low pressures and have quick media fill or dump for air, inert gases, water and light oils for 10CST or less.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET HOUSING | VALVE NUMBER CONDUIT HOUSING | |
|---|---|---|---|---|---|
| AC | DC | ||||
| 200 | 200 | 1/2 | 3.50 | 829B11DGM | 829B11DCM |
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (829B11DGM 120/60) repair pack (K829BD AC)
No operator available


A complete line of valves with a great selection of options and exceptional proven performance. The standard in the field. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.
| + MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET HOUSING | VALVE NUMBER CONDUIT HOUSING | |||||
|---|---|---|---|---|---|---|---|---|---|
| AC | DC | 1/8 NPT PORTS | 1/4 NPT PORTS | 1/8 NPT PORTS | 1/4 NPT PORTS | ||||
| 400 | (700)* | 400 | (700)* | 1/32 | .024 | 21G7XGM | 21G9ZGM | 21G7XCM | 21G9ZCM |
| 235 | (500) | 235 | (500) | 3/64 | .053 | 21H7XGM | 21H9ZGM | 21H7XCM | 21H9ZCM |
| 150 | (350) | 150 | (350) | 1/16 | .095 | 21J7XGM | 21J9ZGM | 21J7XCM | 21J9ZCM |
| 100 | (150) | 100 | (150) | 3/32 | .156 | 21K7XGM | 21K9ZGM | 21K7XCM | 21K9ZCM |
| 35 | (40) | 35 | (40) | 1/8 | .201 | 21N7XGM ^ | 21N9ZGM ^ | 21N7XCM ^ | 21N9ZCM ^ |
^ VALVES WITH 1/8 N.O. ORIFICE ARE UL LISTED ONLY
* FKM seals not recommended for pressure ratings above 500 PSI.
+ Ratings in brackets are optional extended ratings; consult factory
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (21J9ZGM 120/60) repair pack (K21JDX AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O21JDZGM 120/60)



































A complete line of valves with a great selection of options and exceptional proven performance. The standard in the field. For use with air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET HOUSING | VALVE NUMBER CONDUIT HOUSING | ||
|---|---|---|---|---|---|---|
| DC | 1/8 NPT PORTS | 1/4 NPT PORTS | 1/8 NPT PORTS | 1/4 NPT PORTS | ||
| 1750* | 1/32 | .024 | BP21G7DGM | BP21G9DGM | BP21G7DCM | BP21G9DCM |
| 650* | 3/64 | .053 | BP21H7DGM | BP21H9DGM | BP21H7DCM | BP21H9DCM |
| 350 | 1/16 | .095 | BP21J7DGM | BP21J9DGM | BP21J7DCM | BP21J9DCM |
| 200 | 3/32 | .156 | BP21K7DGM | BP21K9DGM | BP21K7DCM | BP21K9DCM |
| 100 | 1/8 | .201 | BP21N7DGM | BP21N9DGM | BP21N7DCM | BP21N9DCM |
* FKM seals not recommended for pressure above 500 psi.
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (BP21K9DGM 120/60) repair pack (KBP21KDD DC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OBP21KDDGM 120/60)



































Easily interfaced with circuit boards and miniaturized components. The versatility is for connecting electronic signals to pneumatic outputs. The small size is ideal for stand alone (with #10-32 UNF-2B ports) or multiple valves mounted on one manifold. Air and other common gases — filtration recommended — 30 microns or less.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER | ||
|---|---|---|---|---|---|
| DC | INLET | EXH | INLET | EXH | LEADWIRE |
| 145 | 0.6 mm | 0.6 mm | .010 | .010 | 584AA19PGM |
| 100 | 0.8 mm | 0.8 mm | .020 | .020 | 584FF19PGM |
| 50 | 1.0 mm | 1.0 mm | .030 | .030 | 584MM19PGM |
| 40 | 1.2 mm | 1.2 mm | .034 | .034 | 584WW19PGM |
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (584MM19PGM 12/DC) repair pack (K584MM19D DC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O584MMDPGM 12/DC)






The little black box — magnetic components encased in epoxy for durability and reliability. Interior parts are stainless steel and anodized aluminum. The valves may be used with air, inert gas and liquid media at pressures from vacuum to 150 psi — depending upon orifice size and configuration. For those who require extra heat resistance and media compatibility, FKM and other elastomers are available.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER LEAD WIRE | VALVE NUMBER DIN STYLE | VALVE NUMBER CONDUIT HOUSING | |||
|---|---|---|---|---|---|---|---|---|
| AC | DC | INLET | EXH | INLET | EXH | |||
| 150 | 150 | 1/32 | 1/32 | .020 | .022 | 154GG2XGM | 154GG2XEM | 154GG2XCM |
| 125 | 125 | 3/64 | 3/64 | .048 | .055 | 154HH2XGM | 154HH2XEM | 154HH2XCM |
| 100 | 100 | 1/16 | 1/16 | .075 | .075 | 154JJ2XGM | 154JJ2XEM | 154JJ2XCM |
| 75 | 75 | 1/16 | 3/32 | .075 | .130 | 154JK2XGM | 154JK2XEM | 154JK2XCM |
| 50 | 50 | 3/32 | 3/32 | .130 | .130 | 154KK2XGM | 154KK2XEM | 154KK2XCM |
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (154JJ2XGM 120/60) repair pack (K154JX AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O154JJDXGM 120/60)






Complete range of valves particularly suitable when cost and size are major factors. The bodies are constructed of brass (stainless steel is optional). Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET HOUSING | VALVE NUMBER CONDUIT HOUSING | |||
|---|---|---|---|---|---|---|---|
| AC | DC | INLET | EXH | INLET | EXH | 1/8 NPT PORTS | 1/8 NPT PORTS |
| 300 | 300 | 1/32 | 1/32 | .024 | .024 | 34GG5XGM | 34GG5XCM |
| 175 | 175 | 3/64 | 1/16 | .052 | .095 | 34HJ5XGM | 34HJ5XCM |
| 100 | 100 | 1/16 | 3/32 | .095 | .160 | 34JK5XGM | 34JK5XCM |
| 60 | 60 | 3/32 | 1/8 | .160 | .275 | 34KN5XGM | 34KN5XCM |
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (34HJ5XCM 120/60) repair pack (K34HJX AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O34HJDXCM 120/60)





A complete line of valves with a great selection of options and exceptional proven performance. The standard in the field. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.
| + MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET HOUSING | VALVE NUMBER CONDUIT HOUSING | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| AC | DC | INLET | EXH | INLET | EXH | 1/8 NPT PORTS | 1/4 NPT PORTS | 1/8 NPT PORTS | 1/4 NPT PORTS | |
| 400 | 400 | 1/32 | 1/32 | .024 | .024 | 24GG7XGM | 24GG9ZGM | 24GG7XCM | 24GG9ZCM | |
| 150 | (225) | 150 | 3/64 | 1/16 | .052 | .095 | 24HJ7XGM | 24HJ9ZGM | 24HJ7XCM | 24HJ9ZCM |
| 100 | (150) | 100 | 1/16 | 1/16 | .095 | .095 | 24JJ7XGM | 24JJ9ZGM | 24JJ7XCM | 24JJ9ZCM |
| 100 | (150) | 100 | 1/16 | 3/32 | .095 | .156 | 24JK7XGM | 24JK9ZGM | 24JK7XCM | 24JK9ZCM |
| 100 | (125) | 100 | 1/16 | 1/8 | .095 | .284 | 24JN7XGM^ | 24JN9ZGM^ | 24JN7XCM^ | 24JN9ZCM^ |
| 75 | (90) | 75 | 3/32 | 1/8 | .156 | .284 | 24KN7XGM^ | 24KN9ZGM^ | 24KN7XCM^ | 24KN9ZCM^ |
| 30 | 30 | 1/8 | 1/8 | .201 | .284 | 24NN7XGM^ | 24NN9ZGM^ | 24NN7XCM^ | 24NN9ZCM^ | |
^ VALVES WITH 1/8 N.O. ORIFICE ARE UL LISTED ONLY
+ Ratings in brackets are optional extended ratings; consult factory.
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (24JK9ZGM 120/60) repair pack (K24JKX AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O24JKDZGM 120/60)










































Using the heart of the highly successful model H22, Peter Paul Electronics Co., Inc., has a valve that allows the same media control as a three way normally open valve but at much higher pressure ratings than previously available. Pressure applied to the "IN" port must always be equal to or greater than the pressure in "CYL" port. Air and other non-corrosive gases, water and oil.
| MAX. OPER. PRESS. DIFF. | ORIFICE SIZE | CV FACTOR | VALVE NUMBER GROMMET HOUSING | VALVE NUMBER CONDUIT HOUSING | ||||
|---|---|---|---|---|---|---|---|---|
| DC | INLET | EXH | INLET | EXH | 1/8 NPT PORTS | 1/4 NPT PORTS | 1/8 NPT PORTS | 1/4 NPT PORTS |
| 1000* | 0.6 mm | 1/32 | .010 | .022 | H24MG7XGM | H24MG9ZGM | H24MG7XCM | H24MG9ZCM |
* FKM seals not recommended for pressure above 500 psi.
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (H24MG7XGM 12/DC) repair pack (KH24MGX DC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OH24MGDXGM 12/DC)