Series L58 Model L583 - Piped Exhaust

Series L58 Model L583 - Piped Exhaust
Series L58 Model L583 - Piped Exhaust flow diagram

Easily interfaced with circuit boards and miniaturized components. The versatility is for connecting electronic signals to pneumatic outputs. The small size is ideal for stand-alone use with #10-32 ports or multiple valves mounted on one manifold. Air and other common gases; filtration recommended, 30 microns or less.

  • May be used to pilot larger valves.
  • Ideal for micro electronic production equipment.
  • Great for medical and chemical analytical applications.
  • Can operate directly from most programmable controllers.
  • High quality engineering.

VALVE SPECIFICATIONS

Valve specifications — Series L58 Model L583 - Piped Exhaust
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORVALVE NUMBER
DCINLETEXHINLETEXH
1450.6 mm0.6 mm.010.010L583AA19PGM
1450.6 mm0.8 mm.010.020L583AF19PGM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (L583AF19PGM 12/DC) repair pack (L583AF19G DC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OL583AFDPGM 12/DC)


Coil Voltage
12, 24/DC
Nominal Power
DC — 0.9 Watts
Coil Construction
Molded Class A with leadwires (Std.), Micro DIN (Opt.)
Typical Response Time on Air
DC - 9 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
#10-32 and Manifold Mount
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.13 lbs
Repair Packs
See table above.
Options
Round Stainless Steel, Male Stud Mount, and Manifold Mount*
Media
Air and other common gasses - filtration recommended - 30 microns or less.
Valve Temperature Range
Standard Valves – 5°F (-15°C) to 122°F (50°C) ambient and media. Note Do not allow water to freeze when using plastic body.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
1500 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

 

Series L58 Model L583 Piped Leads Connection

Technical drawing — MODEL L583 3WNC PIPED EXHAUST MOLDED COIL WITH LEADS PLASTIC BODY WITH 10-32 PORTS
MODEL L583 3WNC PIPED EXHAUST MOLDED COIL WITH LEADS PLASTIC BODY WITH 10-32 PORTS
Technical drawing — MODEL L583 3WNC PIPED EXHAUST MOLDED LEAD STYLE COIL STAINLESS STEEL BODY WITH 10-32 PORTS
MODEL L583 3WNC PIPED EXHAUST MOLDED LEAD STYLE COIL STAINLESS STEEL BODY WITH 10-32 PORTS
Technical drawing — MODEL L583 3WNC PIPED EXHAUST MOLDED LEADS COIL MANIFOLD MOUNT PLASTIC BODY
MODEL L583 3WNC PIPED EXHAUST MOLDED LEADS COIL MANIFOLD MOUNT PLASTIC BODY
Technical drawing — MODEL L583 3WNC PIPED EXHAUST MOLDED LEADS COIL STUD MANIFOLD MOUNT WITH STAINLESS STEEL BODY
MODEL L583 3WNC PIPED EXHAUST MOLDED LEADS COIL STUD MANIFOLD MOUNT WITH STAINLESS STEEL BODY
Polyester Plastic (Std.), Stainless Steel (Opt.)

Series 58 Operators Molded Leads

Technical drawing — MODEL OL583  PIPED EXHAUST 3WNC MOLDED COIL WITH LEADS
MODEL OL583
PIPED EXHAUST
3WNC MOLDED COIL WITH LEADS

Series EL50 Model EL53 - Piped Exhaust

Series EL50 Model EL53 - Piped Exhaust
Series EL 50 Model EL53 - Piped Exhaust flow diagram

PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.

  • Miniature Hazardous Location valves using even less power than an E53.
  • Flame-proof construction.
  • High quality engineering.
Valve specifications — Series EL 50 Model EL53 - Piped Exhaust
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
ACDCINLETEXHINLETEXH
1201201/321/32.022.048EL53GG8XCCM-∆
1201201/323/64.055.048EL53GH8XCCM-∆
60603/643/64.055.048EL53HH8XCCM-∆
30301/161/16.075.075EL53JJ8XCCM-∆

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (EL53HH8XCCM 120/60) repair pack (5KEL53HHX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OEL53HHDXCCM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 1.8 Watts, DC — 1.8 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D - Class II, Div 1, Groups E, F, and G: Div 2, Groups A, B, C, D, E, F, and G.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.65 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*
Media
Air and other common gases and common refrigerants except ammonia, city gas supplies by public utilities, Nos. 1 and 2 fuel oils, oils having viscosities not more than 40, SU at 100° F, steam, some hydraulic and water or other aqueous non-flammable liquid
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series EL 50 Hazardous Location Valves

Technical drawing — MODEL EL53 1/8-27 NPT 3WNC PIPED EXHAUST EXPLOSION PROOF
MODEL EL53
1/8-27 NPT
3WNC PIPED EXHAUST EXPLOSION PROOF

Technical drawing — MODEL EL53 10-32 PORTS 3WNC PIPED EXHAUST EXPLOSION PROOF
MODEL EL53
10-32 PORTS
3WNC PIPED EXHAUST EXPLOSION PROOF

Technical drawing — MODEL EL53 BODY OPTION "E" 3WNC PIPED EXHAUST EXPLOSION PROOF
MODEL EL53
BODY OPTION "E"
3WNC PIPED EXHAUST EXPLOSION PROOF

Technical drawing — MODEL EL53 BODY OPTION "O" 3WNC PIPED EXHAUST EXPLOSION PROOF
MODEL EL53
BODY OPTION "O"
3WNC PIPED EXHAUST EXPLOSION PROOF

Technical drawing — MODEL EL53 BODY OPTION "R" 3WNC PIPED EXHAUST EXPLOSION PROOF
MODEL EL53
BODY OPTION "R"
3WNC PIPED EXHAUST EXPLOSION PROOF

Technical drawing — MODEL EL53 METERED BODY 3WNC PIPED EXHAUST EXPLOSION PROOF
MODEL EL53
METERED BODY
3WNC PIPED EXHAUST EXPLOSION PROOF

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 
Stainless Steel (Std.)

Series 50 Operators Explosion Proof

Technical drawing — MODEL OEL53 3WNC PIPED EXHAUST EXPLOSION PROOF
MODEL OEL53 3WNC PIPED EXHAUST EXPLOSION PROOF
Certification
North American

Series 20 Model MLV25 (REVERSE POLARITY)

Series 20 Model MLV25 (REVERSE POLARITY)
Series 20 Model MLV25 (REVERSE POLARITY) solenoid operator
2 wire coil wiring diagram
DIN coil (2 terminals with ground) wiring diagram
Series 20 Model MLV25 (REVERSE POLARITY) flow diagram

3-Way Directional Control Reverse Polarity Valve - This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited, as it only uses power during latching and un-latching. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.

Neutral (−) a. Pulse Yellow lead to Positive (+) to latch   b. Pulse Blue lead to Positive (+) to un-latch  

Positive (+) a. Pulse Yellow lead to Neutral (−) to un-latch   b. Pulse Blue lead to Neutral (−) to latch  

VALVE SPECIFICATIONS

Valve specifications — Series 20 Model MLV25 (REVERSE POLARITY)
MAX. OPER.ORIFICE SIZECV FACTORVALVE NUMBER
DIN COIL (2 TERMINALS WITH GROUND)
VALVE NUMBER
2 WIRE COIL
PRESS. DIFF.
DCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS1/8 NPT PORTS1/4 NPT PORTS
500*1/321/32.024.02425GG7XELM-∆25GG9ZELM-∆25GG7XGLM-∆25GG9ZGLM-∆
2353/643/64.052.05225HH7XELM-∆25HH9ZELM-∆25HH7XGLM-∆25HH9ZGLM-∆
2001/163/64.095.05225JH7XELM-∆25JH9ZELM-∆25JH7XGLM-∆25JH9ZGLM-∆
1501/161/16.095.09525JJ7XELM-∆25JJ9ZELM-∆25JJ7XGLM-∆25JJ9ZGLM-∆
1003/323/32.156.15625KK7XELM-∆25KK9ZELM-∆25KK7XGLM-∆25KK9ZGLM-∆
1001/83/32.214.15625NK7XELM-∆25NK9ZELM-∆25NK7XGLM-∆25NK9ZGLM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (25JJ7XELM-∆ 12/DC) repair pack (K25JJXL DC)


Coil Voltage
6, 9, 12, 24/DC
Nominal Power
DC — 10.0 Watts
Coil Construction
Molded Class B with DIN 43650 Form A Connector (Std.), Leadwires (Opt.) For your convenience we have the female DIN style mating connector No. 20-198** available for an additional fee.*
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/8” and 1/4” NPT (other ports available).*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns

Series MLV20 Model 25 Magnetic Latching (Reverse Polarity)

Technical drawing — MODEL 25 1/4-18 NPT 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL
MODEL 25
1/4-18 NPT
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL

Technical drawing — MODEL 25 1/8-27 NPT 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL
MODEL 25
1/8-27 NPT
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL

Technical drawing — MODEL 25 BODY OPTION "E" 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL
MODEL 25
BODY OPTION "E"
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL

Technical drawing — MODEL 25 BODY OPTION "O" 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL
MODEL 25
BODY OPTION "O"
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL

Technical drawing — MODEL 25 BODY OPTION "R" 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL
MODEL 25
BODY OPTION "R"
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL

Technical drawing — MODEL 25 METERING 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL
MODEL 25
METERING
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL

Technical drawing — MODEL 25 1/4-18 NPT 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS
MODEL 25
1/4-18 NPT
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS

Technical drawing — MODEL 25 1/8-27 NPT 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS
MODEL 25
1/8-27 NPT
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS

Technical drawing — MODEL 25 BODY OPTION "E" 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS
MODEL 25
BODY OPTION "E"
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS

Technical drawing — MODEL 25 BODY OPTION "O" 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS
MODEL 25
BODY OPTION "O"
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS

Technical drawing — MODEL 25 BODY OPTION "R" 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS
MODEL 25
BODY OPTION "R"
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS

Technical drawing — MODEL 25 METERING 3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS
MODEL 25
METERING
3-WAY DIRECTIONAL CONTROL MAGNETIC LATCHING COIL WITH LEADS

Stainless Steel (Std.) or Brass (Opt.)

Series E50 Model E53 - Exhaust to Atmosphere

Series E50 Model E53 - Exhaust to Atmosphere
Series E50 Model E53 - Exhaust to Atmosphere flow diagram

PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.

  • Miniature Hazardous Location valve.
  • Flame-proof construction.
  • High quality engineering.

VALVE SPECIFICATIONS

Valve specifications — Series E50 Model E53 - Exhaust to Atmosphere
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
ACDCINLETEXHINLETEXH
2002001/321/32.022.020E53GG8DCCM-∆
1501503/643/64.055.048E53HH8DCCM-∆
1501503/641/16.055.075E53HJ8DCCM-∆
1001001/161/16.075.075E53JJ8DCCM-∆
60603/321/16.156.075E53KJ8DCCM-∆
50503/323/32.156.156E53KK8DCCM-∆
30301/81/16.230.075E53NJ8DCCM-∆
30301/83/32.230.156E53NK8DCCM-∆

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (E53HJ8DCCM 120/60) repair pack (5KE53HJD AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE53HJDDCCM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 5.6 Watts DC — 7.2 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D - Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.40 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers, All Stainless Steel Construction*
Media
Air, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series E50 Hazardous Location Valves

Technical drawing — MODEL E53 1/8-27 NPT 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
MODEL E53
1/8-27 NPT
3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF

Technical drawing — MODEL E53 10-32 BODY PORTS 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
MODEL E53
10-32 BODY PORTS
3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF

Technical drawing — MODEL E53 BODY OPTION "E" 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
MODEL E53
BODY OPTION "E"
3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF

Technical drawing — MODEL E53 BODY OPTION "O" 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
MODEL E53
BODY OPTION "O"
3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF

Technical drawing — MODEL E53 BODY OPTION "R" 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
MODEL E53
BODY OPTION "R"
3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF

Technical drawing — MODEL E53 METERED BODY 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
MODEL E53
METERED BODY
3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Stainless Steel (Std.)

Series 50 Operators Explosion Proof

Technical drawing — MODEL OE53 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
MODEL OE53 3WNC EXHAUST TO ATMOSPHERE EXPLOSION PROOF
Certification
North American

Series 70 Model N76

Series 70 Model N76
Series 70 Model N76 flow diagram

The 70 line PeterPaul Hazardous Location valves are UL listed and certified for non-incendive Hazardous Locations — Class I, Div 2, Groups A, B, C and D; Class II, Div 2, Groups E, F and G; T3C temperature rating.

  • Largest direct acting non-piloted valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
Valve specifications — Series 70 Model N76
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
CONDUIT HOUSING
ACDCN.C.N.O.N.C.N.O.1/4 NPT PORTS
2252251/161/16.09.09N76JJ9ZCP
1501503/323/32.22.22N76KK9ZCP
1001001/81/8.35.35N76NN9ZCP
75755/325/32.45.45N76OO9ZCP
60603/163/16.50.50N76PP9ZCP

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N76KK9ZCP 120/60) repair pack (NK76KKX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (ON76KKDZCP 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers * Consult representative or factory for options and specifications.
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 70 HAZARDOUS LOCATION VALVES

Technical drawing — MODEL N76 1/4-18 NPT 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL N76
1/4-18 NPT
3-WAY MULTI-PURPOSE CONDUIT CONNECTION

Technical drawing — MODEL N76 1/4-18 NPT 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL N76
1/4-18 NPT
3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Stainless Steel (Std.) or Brass (Opt.)
Certification
North American

Series 20 Model H23 - Piped Exhaust

Series 20 Model H23 - Piped Exhaust
Series 20 Model H23 - Piped Exhaust flow diagram

PeterPaul’s model H23 has a dual operator valve that allows the same media control as a three-way normally closed valve but at much higher pressure ratings than previously available. To function as a 3-way normally closed valve, operators must be alternately energized and de-energized. Pressure applied to the “IN” port must always be equal to or greater than the pressure in the “CYL” port. Air and other non-corrosive gases, water, and oil.

  • Made for higher pressure ratings.
  • Precision stainless steel, free-floating plunger.
  • Kel-F pin sealing element.
  • Orifice guides the sealing pin for near-perfect alignment.
Valve specifications — Series 20 Model H23
GAS PRESSURE RATINGSORIFICE SIZECV FACTORVALVE NUMBER
ACDC1/4 NPT PORTS
3000*3000*1/32.022H23GG19DCMG
2500*1500*3/64.041H23HH19DCMG
1750*5001/16.065H23JJ19DCMG
650*1003/32.100H23KK19DCMG
LIQUID PRESSURE RATINGSORIFICE SIZECV FACTORVALVE NUMBER
ACDC1/4 NPT PORTS

3000*3000*1/32.022H23GG19DCML
1500*1500*3/64.041H23HH19DCML
1000*5001/16.065H23JJ19DCML
3001003/32.100H23KK19DCML

* FKM seals not recommended for pressure above 500 psi.

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (H23JJ19DCMG 120/60) repair pack (KH23JJ AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OH23JJDDCMG 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 7.3 Watts DC — 9.5 Watts (Per Operator)
Coil Construction
Molded (Std.) and Potted Class F or Class H (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM with gas media
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Sealing Pin
Kel-F (Std.), Delrin®, PEEK
Orifice Diameter
See table above.
Porting
1/4" NPT
Housing
Grommet or 1/2" NPT conduit
Mounting
Must be mounted within 30° of vertical.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
3.63 lbs
Repair Packs
See table above.
Options
Alternate Sealing Pin Materials and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102*
Media
Air and other non-corrosive gasses, water and oil.
Filtration
Down to 60 microns or less is recommended.
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
10,000 PSI
Leakage
Bubbletight (with polymer sealing pins)

Series 20 High Pressure Valves Conduit

Technical drawing — MODEL H23 3WNC HIGH PRESSURE CONDUIT CONNECTION
MODEL H23 3WNC HIGH PRESSURE CONDUIT CONNECTION
300 Series Stainless Steel

Series 70 Model N75

Series 70 Model N75
Series 70 Model N75 flow diagram

The N70 line PeterPaul Hazardous Location valves are UL listed and certified for non-incendive Hazardous Location Class 1, Div 2, Groups A, B, C and D; Class 2, Div 2, Groups E, F and G; T3C temperature rating.

  • Largest direct acting non-piloted valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
Valve specifications — Series 70 Model N75
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
GROMMET HOUSING
ACDCN.O.N.C.N.O.N.C.1/4 NPT PORTS
3503501/161/16.09.09N75JJ9ZCP
2502503/323/32.22.22N75KK9ZCP
1751751/81/8.35.35N75NN9ZCP
1251255/325/32.45.45N75OO9ZCP
1001003/163/16.50.50N75PP9ZCP

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N75OO9ZCP 120/60) repair pack (KN75OOX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (ON75OODZCP 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Potted Class F or Class H (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Housing
1/2′′ NPT conduit*
Listings
Listed and Certified for Non-Incendive Hazardous Locations Class 1, Div 2, Groups A, B, C and D; Class 2, Div 2, Groups E, F and G; T3C Temperature rating.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers * Consult representative or factory for options and specifications.
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 70 Hazardous Location Valves

Technical drawing — MODEL N75 1/4-18 NPT 3-WAY DIRECTIONAL CONTROL CONDUIT CONNECTION
MODEL N75
1/4-18 NPT
3-WAY DIRECTIONAL CONTROL CONDUIT CONNECTION

Technical drawing — MODEL N75 1/4-18 NPT 3-WAY DIRECTIONAL CONTROL CONDUIT/BRACKET CONNECTION
MODEL N75
1/4-18 NPT
3-WAY DIRECTIONAL CONTROL CONDUIT/BRACKET CONNECTION

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Stainless Steel (Std.) or Brass (Opt.)
Certification
North American

Series 20 Model MLV22 (FIXED POLARITY)

Series 20 Model MLV22 (FIXED POLARITY)
Series 20 Model MLV22 (FIXED POLARITY) solenoid operator
DIN coil (3 terminals with ground) wiring diagram
3 wire coil wiring diagram
Series 20 Model MLV22 (FIXED POLARITY) flow diagram

2-Way Fixed Polarity Magnet Latching Valve - This type of valve is often used in remote areas where continuous power may not be available or with battery-powered portable equipment where power capacity is limited. It is also valuable in equipment where coil heating, due to continuous application of power, is undesirable. Air, water and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require other seal materials.

There are two ways to latch and un-latch the valve.

Common Black wire set to Neutral (-) a. Pulse Yellow lead to Positive (+) to latch   b. Pulse Blue lead to Positive (+) to un-latch  

Common Black wire set to Positive (+) a. Pulse Yellow lead to Neutral (-) to un-latch   b. Pulse Blue lead to Neutral (-) to latch  

Valve specifications — Series 20 Model MLV22 (FIXED POLARITY)
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
DIN COIL (3 TERMINALS WITH GROUND)
VALVE NUMBER
3 WIRE COIL
DC1/8 NPT PORT1/4 NPT Port1/8 NPT PORTS1/4 NPT PORTS
500*1/32.02422G7D4LM-∆22G9D4LM-∆22G7D3LM-∆22G9D3LM-∆
500*3/64.05222H7D4LM-∆22H9D4LM-∆22H7D3LM-∆22H9D3LM-∆
2151/16.09522J7D4LM-∆22J9D4LM-∆22J7D3LM-∆22J9D3LM-∆
1503/32.15622K7D4LM-∆22K9D4LM-∆22K7D3LM-∆22K9D3LM-∆
1201/8.21422N7D4LM-∆22N9D4LM-∆22N7D3LM-∆22N9D3LM-∆
805/32.40422O7D4LM-∆22O9D4LM-∆22O7D3LM-∆22O9D3LM-∆
353/16.50022P7D4LM-∆22P9D4LM-∆22P7D3LM-∆22P9D3LM-∆
251/4.70022R7D4LM-∆22R9D4LM-∆22R7D3LM-∆22R9D3LM-∆

* FKM seals not recommended for pressures of 500 psi and above.

Ordering Information

Seal Material: Replace ∆ with desired code — Blank = Nitrile (Buna), S = Low Temp Buna, N = FKM*, E = Neoprene, A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. Examples: valve (22J7D3LM 12/DC), repair pack (K22J3L DC)

Coil Voltage
6, 9, 12, 24/DC
Nominal Power
8.0 Watts
Coil Construction
Molded Class B with three - 24” leadwires
Typical Response Time on Air
Approximate 50 millisecond pulse to energize and de-energize.
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) standard. FKM, EPDM, Neoprene and Low Temp Nitrile (Buna) are available.*
Orifice Diameter
See table above.
Porting
1/8” OR 1/4” NPT
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.2 lb average
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102. Consult representative or factory for more options & specifications.
Media
Air, water, and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require other seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5,000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series MLV20 Model 22 Magnetic Latching (Fixed Polarity)

Technical drawing — MODEL 22 3-WIRE 1/8-27 NPT 2WNC MAGNETIC LATCHING COIL WITH LEADS
MODEL 22
3-WIRE 1/8-27 NPT
2WNC MAGNETIC LATCHING COIL WITH LEADS

Technical drawing — MODEL 22 3-WIRE 1/4-18 NPT 2WNC MAGNETIC LATCHING COIL WITH 3 LEADWIRES
MODEL 22
3-WIRE 1/4-18 NPT
2WNC MAGNETIC LATCHING COIL WITH 3 LEADWIRES

Technical drawing — MODEL 22 4 PIN DIN 1/8-27 NPT 2WNC MAGNETIC LATCHING COIL
MODEL 22
4 PIN DIN 1/8-27 NPT
2WNC MAGNETIC LATCHING COIL

Technical drawing — MODEL 22 4 PIN DIN 1/4-18 NPT 2WNC MAGNETIC LATCHING COIL
MODEL 22
4 PIN DIN 1/4-18 NPT
2WNC MAGNETIC LATCHING COIL

Stainless Steel

Series 20 Operators Latching

Technical drawing — MODEL O22 2WNC MAGNETIC LATCHING COIL
MODEL O22 2WNC MAGNETIC LATCHING COIL

Series 20 Operators Latching Leads

Technical drawing — MODEL O22 2WNC MAGNETIC LATCHING COIL WITH LEADS
MODEL O22 2WNC MAGNETIC LATCHING COIL WITH LEADS

Series 70 Ventilator Valve 76X00950GM 24/DC

Series 70 Ventilator Valve 76X00950GM 24/DC

3-Way Dual-Inlet, Single Outlet Direct acting valve switches inlet breath pressure to outlet breath pressure. Can run air to 100% oxygen. Very high CV flow coefficient. Very quiet operation.

  • Very quiet switching operation.
  • Controls the flow of air (up to 100% oxygen).
Valve specifications — Series 70 Ventilator Valve 76X00950GM 24/DC
+ MAX. OPER.
PRESS. DIFF. DC
ORIFICE SIZECV FACTORVALVE NUMBER
21/4"2.276X00950GM 24/DC
Coil Voltage
12, 24/DC
Nominal Power
12.5 Watts
Coil Construction
Molded, Class F.
Duty Cycle
Continuous
Internal Components
Stainless Steel.
Elastomers
Nitrile (Buna).
Orifice Diameter
See table above.
Porting
See drawing
Housing
Grommet with mounting bracket.
Life Expectancy
Over 10 Million cycles.
Valve Weight
2.1325 lbs
Media
Air up to 100% oxygen
Valve Temperature Range
0°F (-18°C) to 104°F (40°C) ambient
Maximum Operating Pressure Differentials
2 psi
Leakage
Bubble tight.

Series 70 3-Way Multi-Purpose Ventilator Valve

Technical drawing — MODEL 76X00950GM 24/DC 3-WAY MULTI-PURPOSE VENTILATOR VALVE
MODEL 76X00950GM
24/DC
3-WAY MULTI-PURPOSE VENTILATOR VALVE
Brass

Series 70 Model 71

Series 70 Model 71
Series 70 Model 71 solenoid operator
Series 70 Model 71 Flow Diagram

Super valves that have ratings that formerly required valves of much greater size. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • Largest direct acting (non-piloted) valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
Valve specifications — Series 70 Model 71
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
VALVE NUMBER
CONDUIT HOUSING
ACDC1/4 NPT PORTS1/4 NPT PORTS
3503501/16.0971J9ZGM71J9ZCM
2502503/32.2271K9ZGM71K9ZCM
1751751/8.3571N9ZGM71N9ZCM
1251255/32.4571O9ZGM71O9ZCM
1001003/16.5071P9ZGM71P9ZCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (71P9ZCM 120/60) repair pack (K71PDX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O71PDZCM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Molded Class F (Std.), Potted and Class H Option
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 2.00 lb Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 70 2WNO DIN STYLE COIL

Technical drawing — MODEL 71 1/4-18 NPT 2WNO DIN STYLE COIL
MODEL 71
1/4-18 NPT
2WNO DIN STYLE COIL

Series 70 General Purpose Valves Conduit

Technical drawing — MODEL 71 1/4-18 NPT 2WNO CONDUIT CONNECTION
MODEL 71
1/4-18 NPT
2WNO CONDUIT CONNECTION

Series 70 General Purpose Valves Grommet

Technical drawing — MODEL 71 1/4-18 NPT 2WNO GROMMET WITH LEADS
MODEL 71
1/4-18 NPT
2WNO GROMMET WITH LEADS

Series 70 General Purpose Valves Grommet/Bracket Connection

Technical drawing — MODEL 71 1/4-18 NPT 2WNO GROMMET/BRACKET WITH LEADS
MODEL 71
1/4-18 NPT
2WNO GROMMET/BRACKET WITH LEADS

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com

Series 70 General Purpose Valves Conduit/Bracket Connection

Technical drawing — MODEL 71 1/4-18 NPT 2WNO CONDUIT/BRACKET CONNECTION
MODEL 71
1/4-18 NPT
2WNO CONDUIT/BRACKET CONNECTION

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Stainless Steel (Std.) or Brass (Opt.)

Series 70 Operators Conduit

Technical drawing — MODEL O71 2WNO CONDUIT CONNECTION
MODEL O71 2WNO CONDUIT CONNECTION

Series 70 Operators Conduit/Bracket Connection

Technical drawing — MODEL O71 2WNO CONDUIT/BRACKET CONNECTION
MODEL O71 2WNO CONDUIT/BRACKET CONNECTION

Series 70 Operators Grommet

Technical drawing — MODEL O71 2WNO GROMMET HOUSING WITH LEADS
MODEL O71 2WNO GROMMET HOUSING WITH LEADS

Series 70 Operators Grommet/Bracket Connection

Technical drawing — MODEL O71 2WNO GROMMET/BRACKET WITH LEADS
MODEL O71 2WNO GROMMET/BRACKET WITH LEADS
We will be closed