PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.
Miniature Hazardous Location valve.
Flame-Proof construction.
High quality engineering.
Valve specifications — Series E50 Model E51
MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
NORTH AMERICAN VALVE NUMBER
AC
DC
400
200
1/32
.020
E51G8XCCM-∆
200
100
3/64
.048
E51H8XCCM-∆
125
60
1/16
.075
E51J8XCCM-∆
40
40
3/32
.150
E51K8XCCM-∆
Ordering Information:
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (E51H8XCCM 120/60) repair pack (5KE51H AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE51HDXCCM 120/60)
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 5.6 Watts DC — 7.2 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D - Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.65 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers, All Stainless Steel Construction*
Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Easily interfaced with circuit boards and miniaturized components. The versatility is for connecting electronic signals to pneumatic outputs. The small size is ideal for stand alone (with #10-32 ports) or multiple valves mounted on one manifold. Air and other common gases - filtration recommended - 30 microns or less.
May be used to "pilot" larger valves.
Ideal for micro electronic production equipment.
Great for medical and chemical analytical applications.
Can operate directly from most programmable controllers.
High quality engineering.
Valve specifications — Series L58 Model L581
MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
VALVE NUMBER
DC
LEAD WIRE
150
0.6 mm
.010
L581A19PGM
130
0.8 mm
.020
L581F19PGM
Ordering Information:
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (L581F19PGM 12/DC) repair pack (KL581F19 DC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OL581FDPGM 12/DC)
Coil Voltage
12, 24/DC
Nominal Power
DC — 0.9 Watts
Coil Construction
Molded Class A with leadwires (Std.), Micro DIN (Opt.)
Typical Response Time on Air
DC - 9 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
#10-32 and Manifold Mount
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.13 lbs
Repair Packs
See table above.
Options
Round Stainless Steel, Male Stud Mount, and Manifold Mount*
Media
Air and other common gasses - filtration recommended - 30 microns or less.
Valve Temperature Range
Standard Valves – 5°F (-15°C) to 122°F (50°C) ambient and media. Note Do not allow water to freeze when using plastic body.
MODEL L5812WNO MOLDED LEADS COIL MANIFOLD MOUNT PLASTIC BODYMODEL L5812WNO MOLDED LEADS STYLE COIL MANIFOLD MOUNT PLASTIC BODY WITH MANUAL OVERRIDEMODEL L5812WNO MOLDED LEAD STYLE COIL STAINLESS STEEL BODY WITH 10-32 PORTSMODEL L5812WNO MOLDED LEADS COIL PLASTIC BODY WITH 10-32 PORTS
General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants and many other media, by the use of different seals. Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.
General purpose valve with reduced power consumption.
Increased versatility.
For pneumatic and hydraulic application.
Increased to handle hot air, water and refrigerants.
High quality engineering.
Valve specifications — Series 50 LW Model LW51
MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
VALVE NUMBER GROMMET 1/8" NPT
VALVE NUMBER CONDUIT 1/8" NPT
GAS
LIQUID
AC
DC
AC
DC
300
200
300
200
1/32
.020
LW51G8XGM
LW51G8XCM
270
120
120
65
3/64
.048
LW51H8XGM
LW51H8XCM
135
50
40
30
1/16
.075
LW51J8XGM
LW51J8XCM
70
35
30
20
5/64
.134
LW51V8XGM
LW51V8XCM
55
30
25
15
3/32
.156
LW51K8XGM
LW51K8XCM
Ordering Information:
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (LW51J8XGM 120/60) repair pack (KLW51JX AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OLW51JDXGM 120/60)
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 2.5 Watts DC — 2.5 Watts
Coil Construction
Non-molded Class A, Molded and potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 0.38 lbs, Conduit Valve: 0.44 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers*
Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
General purpose valves for pneumatic and hydraulic applications. The versatility of these valves is increased to include the handling of hot air, hot water, refrigerants, and many other media by the use of different seals. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials.
General purpose valve with reduced power consumption.
Increased versatility.
For pneumatic and hydraulic applications.
NEMA 4 rating is standard with encapsulated coil.
High quality engineering.
Valve specifications — Series 50 SLW Model SLW51
MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
VALVE NUMBER
GAS
LIQUID
AC
DC
AC
DC
N.O.
N.O.
300
200
300
200
1/32
.020
SLW51G8XCCP
270
120
120
65
3/64
.048
SLW51H8XCCP
135
50
40
30
1/16
.075
SLW51J8XCCP
70
35
30
20
5/64
.134
SLW51V8XCCP
55
30
25
15
3/32
.150
SLW51K8XCCP
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 1.8 Watts DC — 1.8 Watts
Coil Construction
Encapsulated Class F Coil with third wire ground
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Encapsulated with 1/2" NPT conduit
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.60 lbs
Options
Alternate Port Locations, Metering, and Alternate Elastomers*
Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 140°F (60°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
A UL and CSA listed, low watt, miniature hazardous location valve with minimal space and energy requirements in volatile environments. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.
Smallest hazardous location solenoid valve.
Best ambient and high temperature ratings on the market.
NEMA 4 rating is standard with encapsulated coil.
High quality engineering.
Valve specifications — Series 50 ELW Model ELW51
MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
VALVE NUMBER
GAS
LIQUID
AC
DC
AC
DC
N.O.
N.O.
300
200
300
200
1/32
.020
ELW51G8XCCP
270
120
120
65
3/64
.048
ELW51H8XCCP
135
50
40
30
1/16
.075
ELW51J8XCCP
70
35
30
20
5/64
.134
ELW51V8XCCP
55
30
25
15
3/32
.150
ELW51K8XCCP
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 1.8 Watts DC — 1.8 Watts
Coil Construction
Encapsulated Class F Coil with third wire ground
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Encapsulated with 1/2" NPT conduit
Listings
Valves are UL listed for Hazardous Locations — Class I, Div 1, Groups A, B, C, and D - Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G. "T" Rating as low as T5.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.60 lbs
Options
Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*
Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 140°F (60°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
PeterPaul offers large orifice solenoid valves to address process industry requirements for high flow rate or quick dump and fill capacity. These AC or DC powered valves are suited for gas and liquid applications. Port sizes for pilot lift, two way normally closed 1/2” to 1” NPT, with pressure differentials from 3 to 200 PSI.
Large orifice sizes for high flow applications.
Body materials as listed.
Pilot operated.
NPT threaded connections.
Same coils and housings as our popular 20 Series.
Valve specifications — Series 80 Model 828
MAX. OPER. PRESS. DIFF.
MIN. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
VALVE NUMBER GROMMET HOUSING
VALVE NUMBER CONDUIT HOUSING
PROCESS CONNECTION
AC
DC
200
200
3
1/2
4.0
828B12DGM
828B12DCM
1/2"
200
200
3
1
9.0
828D29DGM
828D29DCM
3/4"
200
200
3
1
13.0
828D23DGM
828D23DCM
1"
Ordering Information:
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (828B12DGM 120/60) repair pack (K828B12DD AC)
No operator available
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 7.7 Watts DC — 9.5 Watts
Coil Construction
Molded Class F, (Opt.) Potted Class F or Class H
Operating Speed
Up to 100 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.).
Orifice Diameter
See table above.
Housing
Grommet and 1/2" NPT conduit
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Repair Packs
See table above.
Options
Spade Terminal Coil, DIN, and Magnetic Latching Coil
Media
Air, water, and other fluids compatible with Buna seals.(Series 80 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
A complete line of valves with a great selection of options and exceptional proven performance. Using the heart of the highly successful model H22, Peter Paul Electronics Co., Inc., has a dual operator valve that allows the same media control as a three way normally closed valve but at much higher pressure ratings than previously available. To function as a 3-way normally closed valve, operators must be alternately energized and de-energized. Pressure applied to the "IN" port must always be equal to or greater than the pressure in "CYL" port. Air and other non-corrosive gasses, water and oil.
Made for higher pressure ratings.
Precision stainless steel, free floating plunger.
Kel-F pin sealing element.
Orifice guides the sealing pin for near perfect alignment.
Simple construction...only two moving parts.
Explosion proof construction.
Valve specifications — Series 20 Model EH23
GAS PRESSURE RATINGS
ORIFICE SIZE
CV FACTOR
NORTH AMERICAN VALVE NUMBER
IECEx/ATEX VALVE NUMBER
AC
DC
1/4 NPT PORTS
1/4 NPT PORTS
3000*
3000*
1/32
.022
EH23GG19DCCM-∆
EHA23GG19DCCM-∆
2500*
1500*
3/64
.041
EH23HH19DCCMG-∆
EHA23HH19DCCMG-∆
1750*
500
1/16
.065
EH23JJ19DCCMG-∆
EHA23JJ19DCCMG-∆
650*
100
3/32
.100
EH23KK19DCCMG-∆
EHA23KK19DCCMG-∆
LIQUID PRESSURE RATINGS
ORIFICE SIZE
CV FACTOR
NORTH AMERICAN VALVE NUMBER
IECEx/ATEX VALVE NUMBER
AC
DC
1/4 NPT PORTS
1/4 NPT PORTS
3000*
3000*
1/32
.022
EH23GG19DCCM-∆
EHA23GG19DCCM-∆
1500*
1500*
3/64
.041
EH23HH19DCCML-∆
EHA23HH19DCCML-∆
1000*
500
1/16
.065
EH23JJ19DCCML-∆
EHA23JJ19DCCML-∆
300
100
3/32
.100
EH23KK19DCCML-∆
EHA23KK19DCCML-∆
* FKM seals not recommended for pressure above 500 psi.
Ordering Information:
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (EH23JJ19DCCML 120/60) repair pack (2KEH23JJ AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OEH23JJDDCCML 120/60)
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 7.3 Watts DC — 9.5 Watts (Per Operator)
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM with gas media
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Sealing Pin
Kel-F (Std.), Delrin®, PEEK
Orifice Diameter
See table above.
Porting
1/4" NPT
Housing
Flame-Proof Construction with 1/2″ NPT conduit
Mounting
Must be mounted within 30° of vertical.
Listings
Valves are UL listed for use in the United States and Canada for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2, Groups A, B, C, D, E, F, and G.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
3.63 lbs
Repair Packs
See table above.
Options
Alternate Sealing Pin Materials and Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102*
Media
Air and other non-corrosive gasses, water and oil.
Filtration
Down to 60 microns or less is recommended.
Valve Temperature Range
Standard Valves – 0°F (-18°C) to a maximum of 221°F (105°C) including coil heat rise, ambient and media temperatures. Other temperature ranges available on request — along with specific application parameter information specified.*
PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.
Miniature Hazardous Location valves using even less power than an E52.
Flame-Proof construction.
High quality engineering.
Valve specifications — Series EL 50 Model EL52
MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
NORTH AMERICAN VALVE NUMBER
AC
DC
120
120
1/32
.022
EL52G8DCCM-∆
80
80
3/64
.055
EL52H8DCCM-∆
50
50
1/16
.075
EL52J8DCCM-∆
Ordering Information:
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (EL52H8DCCM 120/60) repair pack (5KEL52H AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OEL52HDDCCM 120/60)
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 1.8 Watts DC — 1.8 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D - Class II, Div 1, Groups E, F, and G: Div 2, Groups A, B, C, D, E, F, and G.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.65 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*
Media
Air and other common gases and common refrigerants except ammonia, city gas supplies by public utilities, Nos. 1 and 2 fuel oils, oils having viscosities not more than 40, SU at 100°F, steam, some hydraulic and water or other aqueous non-flammable liquids
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
A UL and CSA listed, low watt, miniature hazardous location valve with minimal space and energy requirements in volatile environments. Air and other fluids are compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many other media require special seal materials.
Smallest hazardous location solenoid valve.
Best ambient and high temperature ratings on the market.
NEMA 4 rating is standard with encapsulated coil.
High quality engineering.
Valve specifications — Series 50 ELW Model ELW52
MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
NORTH AMERICAN VALVE NUMBER
GAS
LIQUID
AC
DC
AC
DC
N.C.
N.C.
600
200
600
200
1/32
.022
ELW52G8DCCP
250
80
250
80
3/64
.055
ELW52H8DCCP
150
50
150
50
1/16
.075
ELW52J8DCCP
100
25
100
25
5/64
.134
ELW52V8DCCP
85
20
85
20
3/32
.156
ELW52K8DCCP
50
50
1/8
.230
ELW52N8DCCP
15
15
5/32
.292
ELW52O8DCCP
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 1.8 Watts DC — 1.8 Watts
Coil Construction
Encapsulated Class F Coil with third wire ground
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Encapsulated with 1/2" NPT conduit
Listings
Valves are UL listed for Hazardous Locations — Class I, Div 1, Groups A, B, C, and D - Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G. "T" Rating as low as T5.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.60 lbs
Options
Alternate Port Locations, Metering, Alternate Elastomers and All Stainless Steel Construction*
Media
Air and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 140°F (60°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.
Explosion Proof
The flagship valve initially created for the fluid power industry.
Heavy duty and made of stainless steel.
A real workhorse with proven performance.
It has the greatest amount of options available of all the valves.
Wide range of orifice sizes from 1/32" to 1/4".
Valve specifications — Series 20 Model E22
+ MAX. OPER. PRESS. DIFF.
ORIFICE SIZE
CV FACTOR
NORTH AMERICAN VALVE NUMBER
IECEx/ATEX VALVE NUMBER
AC
DC
1/8 NPT PORTS
1/4 NPT PORTS
1/8 NPT PORTS
1/4 NPT PORTS
500
500
1/32
.024
E22G7DCCM-∆
E22G9DCCM-∆
EA22G7DCCM-∆
EA22G9DCCM-∆
250
(500)
250
(500)
3/64
.052
E22H7DCCM-∆
E22H9DCCM-∆
EA22H7DCCM-∆
EA22H9DCCM-∆
200
(400)
200
(400)
1/16
.095
E22J7DCCM-∆
E22J9DCCM-∆
EA22J7DCCM-∆
EA22J9DCCM-∆
125
(300)
125
(250)
3/32
.156
E22K7DCCM-∆
E22K9DCCM-∆
EA22K7DCCM-∆
EA22K9DCCM-∆
100
(200)
100
(200)
1/8
.284
E22N7DCCM-∆
E22N9DCCM-∆
EA22N7DCCM-∆
EA22N9DCCM-∆
75
50
5/32
.404
E22O7DCCM-∆
E22O9DCCM-∆
EA22O7DCCM-∆
EA22O9DCCM-∆
50
25
3/16
.500
E22P7DCCM-∆
E22P9DCCM-∆
EA22P7DCCM-∆
EA22P9DCCM-∆
20
5
1/4
.700
E22R7DCCM-∆
E22R9DCCM-∆
EA22R7DCCM-∆
EA22R9DCCM-∆
+ Ratings in brackets are optional extended ratings; consult factory.
Ordering Information:
Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM
When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (E22N9DCCM 120/60) repair pack (2KE22K AC)
When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE22NDDCCM 120/60)
Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 7.3 Watts DC — 9.5 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" and 1/4" NPT (other ports available).
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are UL listed for use in the United States and Canada for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2, Groups A, B, C, D, E, F, and G.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.38 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Manual Override, Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102*
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*