Series 58 Model 585

Series 58 Model 585
Series 58 Model 585 flow diagram

Easily interfaced with circuit boards and miniaturized components. The versatility is for connecting electronic signals to pneumatic outputs. The small size is ideal for stand alone (with #10-32 UNF-2B ports) or multiple valves mounted on one manifold. Air and other common gases — filtration recommended — 30 microns or less.

  • May be used to "pilot" larger valves.
  • Ideal for micro electronic production equipment.
  • Great for medical and chemical analytical applications.
  • Can operate directly from most programmable controllers.
  • High quality engineering.
Valve specifications — Series 58 Model 585
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
DCN.C.N.O.N.C.N.O.LEADWIRE
3000.6 mm0.6 mm.010.010585AA19PGM
2000.8 mm0.8 mm.020.020585FF19PGM
501.0 mm1.0 mm.030.030585MM19PGM
351.2 mm1.2 mm.034.034585WW19PGM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (585MM19PGM 12/DC) repair pack (K585MM19 DC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O585MMDPGM 12/DC)


Coil Voltage
12, 24/DC
Nominal Power
DC — 3.5 Watts
Coil Construction
Molded Class A with leadwires
Typical Response Time on Air
DC — 9 Milliseconds
Operating Speed
Up to 1000 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
#10-32 UNF-2B
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.13 lbs
Repair Packs
See table above.
Options
Round Stainless Steel, Male Stud Mount, and Manifold Mount*
Media
Air and other common gases — filtration recommended — 30 microns or less.
Valve Temperature Range
Standard Valves – 5°F (-15°C) to 122°F (50°C) ambient; media.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
1500 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 58 Model 585 Molded Leads

Technical drawing — MODEL 585 3-WAY DIRECTIONAL CONTROL MOLDED COIL WITH LEADS PLASTIC BODY WITH 10-32 PORTS
MODEL 585 3-WAY DIRECTIONAL CONTROL MOLDED COIL WITH LEADS PLASTIC BODY WITH 10-32 PORTS
Technical drawing — MODEL 585 3-WAY DIRECTIONAL CONTROL PIPED EXHAUST MOLDED LEAD STYLE COIL STAINLESS STEEL BODY WITH 10-32 PORTS
MODEL 585 3-WAY DIRECTIONAL CONTROL PIPED EXHAUST MOLDED LEAD STYLE COIL STAINLESS STEEL BODY WITH 10-32 PORTS
Technical drawing — MODEL 585 3-WAY DIRECTIONAL CONTROL PIPED EXHAUST MOLDED LEADS COIL MANIFOLD MOUNT PLASTIC BODY
MODEL 585 3-WAY DIRECTIONAL CONTROL PIPED EXHAUST MOLDED LEADS COIL MANIFOLD MOUNT PLASTIC BODY
Technical drawing — MODEL 585 3-WAY DIRECTIONAL CONTROL PIPED EXHAUST MOLDED LEADS COIL STUD MANIFOLD MOUNT WITH STAINLESS STEEL BODY
MODEL 585 3-WAY DIRECTIONAL CONTROL PIPED EXHAUST MOLDED LEADS COIL STUD MANIFOLD MOUNT WITH STAINLESS STEEL BODY
 

 

Polyester Plastic (Std.), Stainless Steel (Opt.)

Series 58 Operators Molded Leads

Technical drawing — MODEL O585 3-WAY DIRECTIONAL CONTROL MOLDED COIL WITH LEADS
MODEL O585 3-WAY DIRECTIONAL CONTROL MOLDED COIL WITH LEADS

Series 15 Model 156

Series 15 Model 156
Series 15 Model 156 flow diagram

The little black box — magnetic components encased in epoxy for durability and reliability. Interior parts are stainless steel and anodized aluminum. The valves may be used with air, inert gas and liquid media at pressures from vacuum to 125 psi — depending upon orifice size and configuration. For those who require extra heat resistance and media compatibility, FKM and other elastomers are available.

  • Small, lightweight and economical.
  • Operating pressures from vacuum to 125 psi.
  • Standard without many options.
Valve specifications — Series 15 Model 156
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
LEAD WIRE
VALVE NUMBER
DIN STYLE
VALVE NUMBER
CONDUIT HOUSING
ACDCN.C.N.O.N.C.N.O.
1251251/321/32.022.020156GG2XGM156GG2XEM156GG2XCM
1001003/643/64.055.048156HH2XGM156HH2XEM156HH2XCM
65501/161/16.075.075156JJ2XGM156JJ2XEM156JJ2XCM
25253/323/32.130.130156KK2XGM156KK2XEM156KK2XCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (156JJ2XEM 120/60) repair pack (K156JX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O156JJDXEM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 8.5 Watts, DC — 10.5 Watts
Coil Construction
Molded Class F. (155°C)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Leadwires, 1/2” NPT Conduit and DIN Style Connector.
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.27 lb to 0.30 lb depending on model and housing style.
Repair Packs
See table above.
Options
Round Brass or Stainless Steel Body, Stackable Construction, Alternate Elastomers and Magnetic Latching Coil. Female DIN Style Connector Part Number 50-17029.*
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 15 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 15 General Purpose Valves

Technical drawing — MODEL 156 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 156 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
Technical drawing — MODEL 156 3-WAY MULTI-PURPOSE DIN STYLE
MODEL 156 3-WAY MULTI-PURPOSE DIN STYLE
Technical drawing — MODEL 156 3-WAY MULTI-PURPOSE MOLDED WITH LEADS
MODEL 156 3-WAY MULTI-PURPOSE MOLDED WITH LEADS
Anodized Aluminum (Std.)

Series 15 Operators Conduit

Technical drawing — MODEL O156 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL O156 3-WAY MULTI-PURPOSE CONDUIT CONNECTION

Series 15 Operators DIN

Technical drawing — MODEL O156 3-WAY MULTI-PURPOSE DIN STYLE
MODEL O156 3-WAY MULTI-PURPOSE DIN STYLE

Series 15 Operators Molded Leads

Technical drawing — MODEL O156 3-WAY MULTI-PURPOSE MOLDED WITH LEADS
MODEL O156 3-WAY MULTI-PURPOSE MOLDED WITH LEADS

Series 50 Model 56

Series 50 Model 56
Series 50 Model 56 solenoid operator
Series 50 Model 56 flow diagram

Our original mini — engineered for space economy without sacrificing performance. Typical applications include medical, analytical instrumentation. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • Tough with options to use in hazardous location environments or low watt applications.
  • High quality engineering.
Valve specifications — Series 50 Model 56
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
VALVE NUMBER
CONDUIT HOUSING
ACDCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/8 NPT PORTS
1251251/321/32.022.02056GG8XGM56GG8XCM
1001003/643/64.055.04856HH8XGM56HH8XCM
65501/161/16.075.07556JJ8XGM56JJ8XCM
25253/323/32.156.15056KK8XGM56KK8XCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (56JJ8XGM 120/60) repair pack (K56JDX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O56JJDXGM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 6.0 Watts, DC — 7.0 Watts
Coil Construction
Molded and potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/8" NPT (other ports available).*
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 0.38 lb Conduit Valve: 0.44 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers, Low Wattage, Spade Terminal Coil and Explosion Proof*
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 50 General Purpose Valves Conduit

Technical drawing — MODEL 56 1/8-27 NPT 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 56
1/8-27 NPT
3-WAY MULTI-PURPOSE CONDUIT CONNECTION
Technical drawing — MODEL 56 STUD MOUNT BODY 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 56
STUD MOUNT BODY
3-WAY MULTI-PURPOSE CONDUIT CONNECTION
 

Series 50 General Purpose Valves Grommet

Technical drawing — MODEL 56 1/8-27 NPT 3-WAY MULTI-PURPOSE GROMMET WITH LEADS
MODEL 56
1/8-27 NPT
3-WAY MULTI-PURPOSE GROMMET WITH LEADS
Technical drawing — MODEL 56 STUD MOUNT BODY 3-WAY MULTI-PURPOSE GROMMET WITH LEADS
MODEL 56
STUD MOUNT BODY
3-WAY MULTI-PURPOSE GROMMET WITH LEADS
 

Series 50 General Purpose Valves Yoke Leads

Technical drawing — MODEL 56 1/8-27 NPT 3-WAY MULTI-PURPOSE YOKE WITH LEADS
MODEL 56
1/8-27 NPT
3-WAY MULTI-PURPOSE YOKE WITH LEADS
Technical drawing — MODEL 56 STUD MOUNT BODY 3-WAY MULTI-PURPOSE YOKE WITH LEADS
MODEL 56
STUD MOUNT BODY
3-WAY MULTI-PURPOSE YOKE WITH LEADS
 

Series 50 General Purpose Valves Yoke Spades

Technical drawing — MODEL 56 1/8-27 NPT 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
MODEL 56
1/8-27 NPT
3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
Technical drawing — MODEL 56 STUD MOUNT BODY 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
MODEL 56
STUD MOUNT BODY
3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
 
Stainless Steel (Std.), Brass (Opt.) or Aluminum (Opt.)

Series 30 Model 36

Series 30 Model 36
Series 30 Model 36 flow diagram

Complete range of valves particularly suitable when cost and size are major factors. The bodies are constructed of brass (stainless steel is optional). Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • Brass body with stainless steel internal construction.
  • A smaller, cost effective alternative to any industry standard.
Valve specifications — Series 30 Model 36
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
VALVE NUMBER
CONDUIT HOUSING
ACDCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/8 NPT PORTS
3003001/321/32.024.02436GG5XGM36GG5XCM
1501503/643/64.052.05236HH5XGM36HH5XCM
75751/161/16.095.09536JJ5XGM36JJ5XCM
50303/323/32.160.16036KK5XGM36KK5XCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (36HH5XCM 120/60) repair pack (K36HHX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O36HHDXCM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 8.0 Watts DC — 8.0 Watts
Coil Construction
Molded (Std.), Non-molded Class A and Potted Class F or Class H (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/8" NPT (other ports available).*
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 0.75 lb Conduit Valve: 0.81 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Manual Override, Alternate Elastomers, Spade Terminal Coil*
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 30 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 30 General Purpose Valves Conduit

Technical drawing — MODEL 36 1/8-27 NPT 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 36
1/8-27 NPT
3-WAY MULTI-PURPOSE CONDUIT CONNECTION

Series 30 General Purpose Valves DIN

Technical drawing — MODEL 36 1/8-27 NPT 3-WAY MULTI-PURPOSE DIN STYLE COIL
MODEL 36
1/8-27 NPT
3-WAY MULTI-PURPOSE DIN STYLE COIL

Series 30 General Purpose Valves Grommet

Technical drawing — MODEL 36 1/8-27 NPT 3-WAY MULTI-PURPOSE GROMMET WITH LEADS
MODEL 36
1/8-27 NPT
3-WAY MULTI-PURPOSE GROMMET WITH LEADS

Series 30 General Purpose Valves Grommet/Bracket Connection

Technical drawing — MODEL 36 1/8-27 NPT 3-WAY MULTI-PURPOSE GROMMET/BRACKET WITH LEADS
MODEL 36
1/8-27 NPT
3-WAY MULTI-PURPOSE GROMMET/BRACKET WITH LEADS
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com

Series 30 General Purpose Valves Conduit/Bracket Connection

Technical drawing — MODEL 36 1/8-27 NPT 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL 36
1/8-27 NPT
3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Brass (Std.) or Stainless Steel (Opt.)

Series 20 Model 26

Peter Paul Series 20 Model 26 Valve
Series 20 Model 26 solenoid operator
Series 20 Model 26 flow diagram

A complete line of valves with a great selection of options and exceptional proven performance. The standard in the field. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • The flagship valve initially created for the fluid power industry.
  • Heavy duty and made of stainless steel.
  • A real workhorse with proven performance.
  • It has the greatest amount of options available of all the valves.
  • Wide range of orifice sizes from 1/32" to 1/8".
Valve specifications — Series 20 Model 26
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
VALVE NUMBER
CONDUIT HOUSING
ACDCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS1/8 NPT PORTS1/4 NPT PORTS
4004001/321/32.024.02426GG7XGM26GG9ZGM26GG7XCM26GG9ZCM
1501503/643/64.052.05226HH7XGM26HH9ZGM26HH7XCM26HH9ZCM
1001001/161/16.095.09526JJ7XGM26JJ9ZGM26JJ7XCM26JJ9ZCM
75753/323/32.156.15626KK7XGM26KK9ZGM26KK7XCM26KK9ZCM
35351/81/8.284.20126NN7XGM^26NN9ZGM^26NN7XCM^26NN9ZCM^

^ VALVES WITH 1/8 N.O. ORIFICE ARE UL LISTED ONLY

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (26JJ9ZGM 120/60) repair pack (K26JJX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O26JJDZGM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 8.7 Watts, DC — 9.5 Watts
Coil Construction
Molded (Std.), Non-molded Class A and Potted Class F or Class H (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/8" and 1/4" NPT (other ports available).*
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 1.13 lb Conduit Valve: 1.19 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Manual Override, Alternate Elastomers, Spade Terminal Coil, European Style DIN, Explosion Proof and Magnetic Latching Coil, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102.*
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 20 General Purpose Valves Conduit

Technical drawing — MODEL 26 1/4-18 NPT 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 26
1/4-18 NPT
3-WAY MULTI-PURPOSE CONDUIT CONNECTION
Technical drawing — MODEL 26 1/8-27 NPT 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 26
1/8-27 NPT
3-WAY MULTI-PURPOSE CONDUIT CONNECTION
Technical drawing — MODEL 26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE CONDUIT CONNECTION
Technical drawing — MODEL 26 METERING 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 26
METERING
3-WAY MULTI-PURPOSE CONDUIT CONNECTION
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 

Series 20 General Purpose Valves DIN

Technical drawing — MODEL 26 1/4-18 NPT 3-WAY MULTI-PURPOSE DIN STYLE COIL
MODEL 26
1/4-18 NPT
3-WAY MULTI-PURPOSE DIN STYLE COIL
Technical drawing — MODEL 26 1/8-27 NPT 3-WAY MULTI-PURPOSE DIN STYLE COIL
MODEL 26
1/8-27 NPT
3-WAY MULTI-PURPOSE DIN STYLE COIL
Technical drawing — MODEL 26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE DIN STYLE COIL
MODEL 26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE DIN STYLE COIL
Technical drawing — MODEL 26 METERING 3-WAY MULTI-PURPOSE DIN STYLE COIL
MODEL 26
METERING
3-WAY MULTI-PURPOSE DIN STYLE COIL
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 

Series 20 General Purpose Valves Grommet

Technical drawing — MODEL 26 1/4-18 NPT 3-WAY MULTI-PURPOSE GROMMET WITH LEADS
MODEL 26
1/4-18 NPT
3-WAY MULTI-PURPOSE GROMMET WITH LEADS
Technical drawing — MODEL 26 1/8-27 NPT 3-WAY MULTI-PURPOSE GROMMET WITH LEADS
MODEL 26
1/8-27 NPT
3-WAY MULTI-PURPOSE GROMMET WITH LEADS
Technical drawing — MODEL 26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE GROMMET HOUSING WITH LEADS
MODEL 26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE GROMMET HOUSING WITH LEADS
Technical drawing — MODEL 26 METERING 3-WAY MULTI-PURPOSE GROMMET HOUSING WITH LEADS
MODEL 26
METERING
3-WAY MULTI-PURPOSE GROMMET HOUSING WITH LEADS
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 

Series 20 General Purpose Valves Yoke Leads

Technical drawing — MODEL 26 1/4-18 NPT 3-WAY MULTI-PURPOSE YOKE WITH LEADS
MODEL 26
1/4-18 NPT
3-WAY MULTI-PURPOSE YOKE WITH LEADS
Technical drawing — MODEL 26 1/8-27 NPT 3-WAY MULTI-PURPOSE YOKE WITH LEADS
MODEL 26
1/8-27 NPT
3-WAY MULTI-PURPOSE YOKE WITH LEADS
Technical drawing — MODEL 26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE YOKE WITH LEADS
MODEL 26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE YOKE WITH LEADS
Technical drawing — MODEL 26 METERING 3-WAY MULTI-PURPOSE MOLDED COIL WITH YOKE
MODEL 26
METERING
3-WAY MULTI-PURPOSE MOLDED COIL WITH YOKE
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 

Series 20 General Purpose Valves Yoke Spades

Technical drawing — MODEL 26 1/4-18 NPT 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
MODEL 26
1/4-18 NPT
3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
Technical drawing — MODEL 26 1/8-27 NPT 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
MODEL 26
1/8-27 NPT
3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
Technical drawing — MODEL 26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
MODEL 26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
Technical drawing — MODEL 26 METERING 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
MODEL 26
METERING
3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 

Series 20 General Purpose Valves Conduit/Bracket Connection

Technical drawing — MODEL 26 1/4-18 NPT 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL 26
1/4-18 NPT
3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Technical drawing — MODEL 26 1/8-27 NPT 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL 26
1/8-27 NPT
3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Technical drawing — MODEL 26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL 26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Technical drawing — MODEL 26 METERING 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL 26
METERING
3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 

Series 20 General Purpose Valves Grommet/Bracket Connection

Technical drawing — MODEL 26 1/4-18 NPT 3-WAY MULTI-PURPOSE GROMMET/BRACKET WITH LEADS
MODEL 26
1/4-18 NPT
3-WAY MULTI-PURPOSE GROMMET/BRACKET WITH LEADS
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Technical drawing — MODEL 26 1/8-27 NPT 3-WAY MULTI-PURPOSE GROMMET/BRACKET WITH LEADS
MODEL 26
1/8-27 NPT
3-WAY MULTI-PURPOSE GROMMET/BRACKET WITH LEADS
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Technical drawing — MODEL 26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS
MODEL 26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Technical drawing — MODEL 26 METERING 3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS
MODEL 26
METERING
3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS
Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Stainless Steel (Std.) or Brass (Opt.)

Series 20 Operators Grommet

Technical drawing — MODEL O26 3-WAY MULT-PURPOSE GROMMET HOUSING WITH LEADS
MODEL O26 3-WAY MULT-PURPOSE GROMMET HOUSING WITH LEADS

Series 20 Operators Conduit

Technical drawing — MODEL O26 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL O26 3-WAY MULTI-PURPOSE CONDUIT CONNECTION

Series 20 Operators Conduit/Bracket Connection

Technical drawing — MODEL O26 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL O26 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION

Series 20 Operators DIN

Technical drawing — MODEL O26 3-WAY MULTI-PURPOSE DIN STYLE COIL
MODEL O26 3-WAY MULTI-PURPOSE DIN STYLE COIL

Series 20 Operators Grommet/Bracket Connection

Technical drawing — MODEL O26 3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS
MODEL O26 3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS

Series 20 Operators Yoke Leads

Technical drawing — MODEL O26 3-WAY MULTI-PURPOSE MOLDED COIL WITH YOKE
MODEL O26 3-WAY MULTI-PURPOSE MOLDED COIL WITH YOKE

Series 20 Operators Yoke Spades

Technical drawing — MODEL O26 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS
MODEL O26 3-WAY MULTI-PURPOSE YOKE WITH SPADE TERMINALS

Series 70 Model 76

Series 70 Model 76
Series 70 Model 76 solenoid operator
Series 70 Model 76 flow diagram

Super valves that have ratings that formerly required valves of much greater size. Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials.

  • Largest direct acting (non-piloted) valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
Valve specifications — Series 70 Model 76
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORVALVE NUMBER
GROMMET HOUSING
VALVE NUMBER
CONDUIT HOUSING
ACDCN.C.N.O.N.C.N.O.1/4 NPT PORTS1/4 NPT PORTS
2252251/161/16.09.0976JJ9ZGM76JJ9ZCM
1501503/323/32.22.2276KK9ZGM76KK9ZCM
1001001/81/8.35.3576NN9ZGM76NN9ZCM
75755/325/32.45.4576OO9ZGM76OO9ZCM
60603/163/16.50.5076PP9ZGM76PP9ZCM

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (76KK9ZGM 120/60) repair pack (K76KKX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (O76KKDZGM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Molded Class F (Std.), Potted and Class H Option
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*.
Housing
Grommet and 1/2" NPT conduit - many options available.*
Listings
Most valves are UL and CSA listed.*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Grommet Valve: 2.00 lb Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers*
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 70 3-WAY MULTI-PURPOSE DIN STYLE COIL

Technical drawing — MODEL 76 1/4-18 NPT 3-WAY MULTI-PURPOSE DIN STYLE COIL
MODEL 76
1/4-18 NPT
3-WAY MULTI-PURPOSE DIN STYLE COIL

 

Series 70 General Purpose Valves Conduit

Technical drawing — MODEL 76 1/4-18 NPT 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL 76
1/4-18 NPT
3-WAY MULTI-PURPOSE CONDUIT CONNECTION

 

Series 70 General Purpose Valves Grommet

Technical drawing — MODEL 76 1/4-18 NPT 3-WAY MULTI-PURPOSE GROMMET WITH LEADS
MODEL 76
1/4-18 NPT
3-WAY MULTI-PURPOSE GROMMET WITH LEADS

 

Series 70 General Purpose Valves Conduit/Bracket Connection

Technical drawing — MODEL 76 1/4-18 NPT 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL 76
1/4-18 NPT
3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 

Series 70 General Purpose Valves Grommet/Bracket Connection

Technical drawing — MODEL 76 1/4-18 NPT 3-WAY MULTI-PURPOSE GROMMET/BRACKET CONNECTION
MODEL 76
1/4-18 NPT
3-WAY MULTI-PURPOSE GROMMET/BRACKET CONNECTION

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 
Stainless Steel (Std.) or Brass (Opt.)

Series 70 Operators Conduit

Technical drawing — MODEL O76 3-WAY MULTI-PURPOSE CONDUIT CONNECTION
MODEL O76 3-WAY MULTI-PURPOSE CONDUIT CONNECTION

Series 70 Operators Conduit/Bracket Connection

Technical drawing — MODEL O76 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION
MODEL O76 3-WAY MULTI-PURPOSE CONDUIT/BRACKET CONNECTION

Series 70 Operators Grommet

Technical drawing — MODEL O76 3-WAY MULTI-PURPOSE GROMMET HOUSING WITH LEADS
MODEL O76 3-WAY MULTI-PURPOSE GROMMET HOUSING WITH LEADS

Series 70 Operators Grommet/Bracket Connection

Technical drawing — MODEL O76 3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS
MODEL O76 3-WAY MULTI-PURPOSE GROMMET/BRACKET HOUSING WITH LEADS

Series E50 Model E56

Series E50 Model E56
Series E50 Model E56 flow diagram

PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.

  • Miniature Hazardous Location valve.
  • Flame-Proof construction.
  • High quality engineering.
Valve specifications — Series E50 Model E56
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
IECEx/ATEX
VALVE NUMBER
ACDCN.C.N.O.N.C.N.O.
1251251/321/32.022.020E56GG8XCCM-∆EA56GG8XCCM-∆
1001003/643/64.055.048E56HH8XCCM-∆EA56HH8XCCM-∆
65501/161/16.075.075E56JJ8XCCM-∆EA56JJ8XCCM-∆
25253/323/32.156.156E56KK8XCCM-∆EA56KK8XCCM-∆

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (E56KK8XCCM 120/60) repair pack (5KE56KK AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE56KKDXCCM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 5.6 Watts DC — 7.2 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" NPT (Std.)
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are UL listed and CSA certified for Hazardous Locations — Class I, Div 1, Group C and D - Class II, Div 1, Groups E, F, and G; Div 2, Groups A, B, C, D, E, F, and G
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
0.65 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Alternate Elastomers, All Stainless Steel Construction*
Media
Air, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, oils, some hydraulic fluids, and many media require special seal materials. (Series 50 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series E50 Hazardous Location Valves

Technical drawing — MODEL E56 1/8-27 NPT 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E56
1/8-27 NPT
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Technical drawing — MODEL E56 10-32 PORTS 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E56
10-32 PORTS
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Technical drawing — MODEL E56 BODY OPTION "E" 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E56
BODY OPTION "E"
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Technical drawing — MODEL E56 BODY OPTION "O" 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E56
BODY OPTION "O"
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Technical drawing — MODEL E56 BODY OPTION "R" 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E56
BODY OPTION "R"
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Technical drawing — MODEL E56 METERED BODY 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E56
METERED BODY
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
 
Stainless Steel (Std.)

Series 50 Operators Explosion Proof

Technical drawing — MODEL OE56 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL OE56 3-WAY MULTI-PURPOSE EXPLOSION PROOF
Certification
North American
IECEx/ATEX
IECEx/ATEX Nomenclature

Coming soon.

Series 20 Model E26

Series 20 Model E26
Series 20 Model E26 Male Connection
Series 20 Model E26 solenoid operator
Series 20 Model E26 flow diagram

PeterPaul explosion proof valves are used where fire or explosion hazards exist due to the presence of flammable gases or vapors, flammable liquids, combustible dust, or easily ignitable fibers. Hazardous Location valves are recommended, or in some cases compulsory, where a high level of protection from explosion is required.

  • Explosion Proof
  • The flagship valve initially created for the fluid power industry.
  • Heavy duty and made of stainless steel.
  • A real workhorse with proven performance.
  • It has the greatest amount of options available of all the valves.
  • Wide range of orifice sizes from 1/32" to 1/4".
Valve specifications — Series 20 Model E26
MAX. OPER.
PRESS. DIFF.
ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
IECEx/ATEX
VALVE NUMBER
ACDCN.C.N.O.N.C.N.O.1/8 NPT PORTS1/4 NPT PORTS1/8 NPT PORTS1/4 NPT PORTS
4004001/321/32.024.024E26GG7XCCM-∆E26GG9ZCCM-∆EA26GG7XCCM-∆EA26GG9ZCCM-∆
1501503/643/64.052.052E26HH7XCCM-∆E26HH9ZCCM-∆EA26HH7XCCM-∆EA26HH9ZCCM-∆
1001001/161/16.095.095E26JJ7XCCM-∆E26JJ9ZCCM-∆EA26JJ7XCCM-∆EA26JJ9ZCCM-∆
75753/323/32.156.156E26KK7XCCM-∆E26KK9ZCCM-∆EA26KK7XCCM-∆EA26KK9ZCCM-∆
35351/81/8.284.277E26NN7XCCM-∆ ^E26NN9ZCCM-∆ ^EA26NN7XCCM-∆ ^EA26NN9ZCCM-∆ ^

^ VALVES WITH 1/8 ORIFICE ARE NOT UL OR CSA RATED

Ordering Information:

Seal Material: Replace ∆ with desired code - Blank = Nitrile (Buna) S = Low Temp Buna. N = FKM* E = Neoprene A = EPDM

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (E26NK9ZCCM 120/60) repair pack (2KE26NK AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (OE26NKDZCCM 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 7.3 Watts, DC — 9.5 Watts
Coil Construction
Molded Class F with third wire ground (Std.), Class H or Potted (Opt.)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
1/8" and 1/4" NPT (other ports available).
Housing
Flame-Proof construction with 1/2" NPT conduit
Listings
Valves are UL listed for use in the United States and Canada for Hazardous Locations — Class I, Div 1, Group C and D – Class II, Div 1, Group E, F, and G; Div 2, Groups A, B, C, D, E, F, and G.
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
1.50 lbs
Repair Packs
See table above.
Options
Alternate Port Locations, Metering, Manual Override, Alternate Elastomers, Female DIN Style Connector Part Numbers DIN COIL (2 TERMINALS W/GROUND) #20-198 & DIN COIL (3 TERMINALS W/GROUND) #20-19102*
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 20 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
5000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 20 Hazardous Location Valves

Technical drawing — MODEL E26 1/4-18 NPT 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E26
1/4-18 NPT
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Technical drawing — MODEL E26 1/8-27 NPT 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E26
1/8-27 NPT
3-WAY MULTI-PURPOSE EXPLOSION PROOF

Technical drawing — MODEL E26 MANUAL OVERRIDE 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL E26
MANUAL OVERRIDE
3-WAY MULTI-PURPOSE EXPLOSION PROOF

 
Stainless Steel (Std.)

Series 20 Operators Explosion Proof

Technical drawing — MODEL OE26 3-WAY MULTI-PURPOSE EXPLOSION PROOF
MODEL OE26 3-WAY MULTI-PURPOSE EXPLOSION PROOF
Certification
North American
IECEx/ATEX
IECEx/ATEX Nomenclature

Coming soon.

Series 70 Model N71

Series 70 Model N71
Series 70 Model N71 flow diagram

The N70 line PeterPaul Hazardous Location valves are UL listed and certified for non-incendive Hazardous Locations — Class I, Div 2, Groups A, B, C and D; Class II, Div 2, Groups E, F and G; T3C temperature rating.

  • Largest direct acting non-piloted valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
Valve specifications — Series 70 Model N71
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
CONDUIT HOUSING
ACDC1/4 NPT PORTS
3503501/16.09N71J9ZCP
2502503/32.22N71K9ZCP
1751751/8.35N71N9ZCP
1251255/32.45N71O9ZCP
1001003/16.50N71P9ZCP

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N71P9ZCP 120/60) repair pack (KN71PDX AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (ON71PDZCP 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers * Consult representative or factory for options and specifications.
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 70 HAZARDOUS LOCATION VALVES

Technical drawing — MODEL N71 1/4-18 NPT 2WNO CONDUIT CONNECTION
MODEL N71
1/4-18 NPT
2WNO CONDUIT CONNECTION

Technical drawing — MODEL N71 1/4-18 NPT 2WNO CONDUIT/BRACKET CONNECTION
MODEL N71
1/4-18 NPT
2WNO CONDUIT/BRACKET CONNECTION

Minimum quantity required. Please contact sales for additional assistance.
sales@peterpaul.com
Stainless Steel (Std.) or Brass (Opt.)
Certification
North American

Series 70 Model N72

Series 70 Model N72
Series 70 Model N72 flow diagram

The N70 line PeterPaul Hazardous Location valves are UL listed and certified for non-incendive Hazardous Locations — Class I, Div 2, Groups A, B, C and D; Class II, Div 2, Groups E, F and G; T3C temperature rating.

  • Largest direct acting non-piloted valve we manufacture.
  • Large orifice.
  • High flow.
  • Will operate effectively at very low pressures or vacuum.
Valve specifications — Series 70 Model N72
MAX. OPER. PRESS. DIFF.ORIFICE SIZECV FACTORNORTH AMERICAN
VALVE NUMBER
CONDUIT HOUSING
ACDC1/4 NPT PORTS
5005003/32.22N72K9DCP
3003001/8.35N72N9DCP
2252255/32.45N72O9DCP
1401403/16.55N72P9DCP
1001001/4.78N72R9DCP

Ordering Information:

When ordering valves or repair packs add voltage and frequency to complete valve number. For example: valve (N72R9DCP 120/60) repair pack (KN72RDD AC)

When ordering operators add the letter “O” to the front of the valve number, replace body port number with the letter “D”: example: operator (ON72RDDCP 120/60)


Coil Voltage
12/DC, 24/DC, 48/DC, 125/DC, 120/60-110/50, 240/60, and 24/60.
Nominal Power
AC — 18.0 Watts DC — 16.0 Watts
Coil Construction
Potted Class F. (Class H optional)
Typical Response Time on Air
4 - 16 Milliseconds
Operating Speed
Up to 600 CPM
Duty Cycle
Continuous
Internal Components
Stainless Steel. Copper – AC Only.
Elastomers
Nitrile (Buna) (Std.). Many other elastomers available.*
Orifice Diameter
See table above.
Porting
Standard 1/4" NPT (other ports available).*
Life Expectancy
Millions of cycles, depending on application, lubrication, etc.
Valve Weight
Conduit Valve: 2.06 lb
Repair Packs
See table above.
Options
Alternate Port Locations, Metering and Alternate Elastomers * Consult representative or factory for options and specifications.
Media
Air, water, and other fluids compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special seal materials. (Series 70 pressure ratings may change due to the viscosity of the liquid.)*
Valve Temperature Range
Standard Valves – 0°F (-18°C) to 104°F (40°C) ambient; 0°F (-18°C) to 150°F (65°C) media. Optional Valves – can tolerate much higher or much lower ambient and media temperatures.*
Maximum Operating Pressure Differentials
See table above.
Burst Pressure
4000 PSI
Leakage
Bubble tight for standard valves.
Vacuum
To 5 Microns*

Series 70 HAZARDOUS LOCATION VALVES

Technical drawing — MODEL N72 1/4-18 NPT 2WNC CONDUIT CONNECTION
MODEL N72
1/4-18 NPT
2WNC CONDUIT CONNECTION

Technical drawing — MODEL N72 1/4-18 NPT 2WNC CONDUIT/BRACKET CONNECTION
MODEL N72
1/4-18 NPT
2WNC CONDUIT/BRACKET CONNECTION

Stainless Steel (Std.) or Brass (Opt.)
Certification
North American
We will be closed

PeterPaul will be closed Monday, October 12th. We will re-open Tuesday, October 13th for regular business hours.  Please feel free to email us using the chat box below.